HOBUT DC Analogue Voltmeter, 100V, 45 x 45 mm,

  • RS-stocknr. 313-564
  • Fabrikantnummer D481MCS100V/2-001
  • Fabrikant HOBUT
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: GB
Productomschrijving

DC Voltage and Current Meters

90° scale arc
Accuracy class 1.5; BS89 and IEC51
Flame retardant case to UL94V0
Fitted with mounting brackets
Operating temperature range -25 → +40°C
Terminal covers available separately
48x48mm ammeters have integral scales; appropriate scales must be chosen and ordered separately for the 72x72 & 96x96mm ammeters

Note

All ammeters are shunt operated and an appropriate 75mV shunt (no. 257-307 typically) must be ordered separately for each meter; the meters cannot be used without them

Specificaties
Kenmerk Waarde
Current Type DC
Cutout Size 45 x 45 mm
Maximum Displayed Value 100V
Minimum Temperature -25°C
Maximum Temperature +40°C
Meter Type Moving Coil
24 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
48,71
(excl. BTW)
58,94
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
€ 48,71
5 - 9
€ 47,23
10 +
€ 45,31
Related Products
EQN / EQB moving-iron instruments for measuring alternating ...
Description:
EQN / EQB moving-iron instruments for measuring alternating current and voltageMeasurement accuracy: Class 1.5With front zero-point regulatorOverload range of 100% with current meters for start-up bridgingProtection rating IP52Incl. pre-mounted, replaceable scaleIncl. mounting frame, terminal cover.
Selector switch moving iron panel meters are housed ...
Description:
Selector switch moving iron panel meters are housed in moulded polycarbonate cases and are designed for the measurement of AC currents. The frequency range of the current ranges from 15-400 Hz and voltages in the frequency range from 15-100 Hz. ...
Performance based on BS6840:Part 17:1991 & IEC 268-17:1990, ...
Description:
Performance based on BS6840:Part 17:1991 & IEC 268-17:1990, which cover dynamic characteristics, frequency response, harmonic distortion, input impedance and temperature rangeCalibrated for use with a 3.6kΩ resistor 4VU above the scale marking so that reference deflection (0VU) is produced by ...
DQB permanent-magnet moving-coil instruments measure direct currentsIf a ...
Description:
DQB permanent-magnet moving-coil instruments measure direct currentsIf a meter rectifier is used, the average value of a rectified alternating current can also be determinedMeasurement accuracy: Class 1.5 (= max. error 1.5% of final value)Front: 96 x 96 mmFor 92 x ...