Sifam Tinsley AC Analogue Voltmeter, 400V, 68 x 68 mm,

  • RS-stocknr. 886-1901
  • Fabrikantnummer EQ74-V69X2N1CAW0ST
  • Fabrikant Sifam Tinsley
Datasheets
Wetgeving en compliance
Niet conform
Land van herkomst: IN
Productomschrijving

Sigma Series DE Panel Meter

These Sigma Series of DE moving iron panel meters are housed in moulded polycarbonate cases and are suitable for the measurement of AC currents for a frequency range of 15-400Hz and voltages in the frequency range of 15-100Hz.

Available in variety of sizes for both Ammeters & Voltmeters
Scale interchangeability
Near linear scale
Glass filled polycarbonate housing
Knife edge pointer
Easily replace able glass and bezel

Sifam Tinsley Moving Iron Panel Meters

Specificaties
Kenmerk Waarde
Current Type AC
Cutout Size 68 x 68 mm
Cutout Height 68mm
Cutout Width 68mm
Maximum Displayed Value 400V
Depth 54mm
Minimum Temperature -10°C
Maximum Temperature +55°C
Minimum Displayed Value 0V
Approvals CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U, 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC
Meter Type Moving Iron
Measurement Range 0 → 400V ac
Series Sigma
2 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
10 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
15,89
(excl. BTW)
19,23
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
€ 15,89
5 - 9
€ 15,41
10 +
€ 14,78
Related Products
EQN / EQB moving-iron instruments for measuring alternating ...
Description:
EQN / EQB moving-iron instruments for measuring alternating current and voltageMeasurement accuracy: Class 1.5With front zero-point regulatorOverload range of 100% with current meters for start-up bridgingProtection rating IP52Incl. pre-mounted, replaceable scaleIncl. mounting frame, terminal cover.
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency ...
Description:
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency range 15 to 400HzOperating temperature range: –25 to +40°CFlame retardant case to UL94V0Panel cut out: 45 x 45mm, 68 x 68mm, 92 x 92mmTerminal covers supplied separately (see accessories).
90° scale arcAccuracy class 1.5; BS89 and IEC51Flame ...
Description:
90° scale arcAccuracy class 1.5; BS89 and IEC51Flame retardant case to UL94V0Fitted with mounting bracketsOperating temperature range -25 → +40°CTerminal covers available separately48x48mm ammeters have integral scales; appropriate scales must be chosen and ordered separately for the 72x72 & 96x96mm ...
Performance based on BS6840:Part 17:1991 & IEC 268-17:1990, ...
Description:
Performance based on BS6840:Part 17:1991 & IEC 268-17:1990, which cover dynamic characteristics, frequency response, harmonic distortion, input impedance and temperature rangeCalibrated for use with a 3.6kΩ resistor 4VU above the scale marking so that reference deflection (0VU) is produced by ...