Block 3.5kVA Open Frame Autotransformer, 200 V ac, 208 V ac Primary, 400 V ac Secondary, 3 UI 114/64 Core

  • RS-stocknr. 738-7812
  • Fabrikantnummer AT3 3,5-20/21-4
  • Fabrikant Block
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

AT3 Series Autotransformers

Range of high efficiency low heat loss 3 phase auto transformers

Common input and output windings
Easy installation-mounting holes provided
Screw terminal connections
Reverse operation posible
Transformers tested to EN 61558-2-13
BLOCKIMPEX vacuum impregnation

Approvals

UL 5085-1/2 CSA 22.2

Specificaties
Kenmerk Waarde
Primary Voltage Rating 200 V ac, 208 V ac
Secondary Voltage Rating 400 V ac
Power Rating 3.5kVA
Construction Open Frame
Mounting Type Chassis Mount, Floor Standing, Wall Mount
Core Type 3 UI 114/64
Termination Type Screw
Length 267mm
Width 150mm
Dimensions 267 x 150 x 220mm
Depth 220mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 17-08-2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
273,89
(excl. BTW)
331,41
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
€ 273,89
5 +
€ 246,52
Related Products
Autowound transformers for step-up or step-down of mains ...
Description:
Autowound transformers for step-up or step-down of mains voltages at 50/60Hz. , Compact construction Full varnish impregnation Fully shrouded Four-hole fixing for permanent installation Terminal blocks with protective covers (except 50VA which has leads) 100% electrical and flash tested (2kV ...
Autowound transformers for step-up or step-down of mains ...
Description:
Autowound transformers for step-up or step-down of mains voltages at 50/60Hz. , Compact construction Full varnish impregnation Fully shrouded Four-hole fixing for permanent installation Terminal blocks with protective covers (except 50VA which has leads) 100% electrical and flash tested (2kV ...
The E-JET step-down autotransformers allow the adjustment and ...
Description:
The E-JET step-down autotransformers allow the adjustment and operation of 110 V appliances connected to 230 V mains.Using autotransformers achieves an approx. 50% lower nominal rating compared to transformers with galvanically isolated windings.To ensure the output voltage to earth is ...
From Block, these short circuit proof encapsulated autowound ...
Description:
From Block, these short circuit proof encapsulated autowound transformers allow step up or step down of mains voltage at 50/60 Hz. Featuring easy to install mounting holes, screw terminal connections with strain relief for connecting leads, a robust and reliable ...