Schneider Electric Contact

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: ID
Productomschrijving

Schneider Electric Auxiliary Contact - LADN TeSys D Series

Are you looking to add an additional auxiliary contact to your control circuit, to provide further safety? Schneider Electric offers the latest in Auxiliary Contact components and technology.

Specifically, the LADN TeSys series of Auxiliary Contactor brings reliability to your circuit by acting as a secondary switching device working in conjunction with other primary devices such as contactors, relays or circuit breakers.

Features and benefits:

• Low consumption on your control circuit
• 30 Mcycles of mechanical durability
• Compact, lightweight and easily attached to compatible contactors. Front side mounting
• Simplified mounting directly to the contactor/circuit breaker. Compact in size and equipped with EverLink terminal technology meaning permanent tightening even in the event with conductor creep
• 18-month manufacturer warranty with Schneider

Protection ratings & Safety features
• IEC 60947-5-1 associated fuse rating
• GG fuse <= 10 A
• BS 4795, EN 60947-5-1, IEC 60947-5-1
• CSA, UL certified
• IP2x Conforming to VDE 0106
• Thermally treated and protected to TH conforming to IEC 60068
• Ambient Air Temperature (AAT) for operation -5 to 60 °C

Applications

• Motor starters/Control systems
• Switching contactors/relay coils
• Control/Signalling equipment

How do Auxiliary Contacts work?

An Auxiliary Contact is an electromechanical device that is mounted typically to contactors. They are physically connected to the contactor, with simultaneous activation and deactivation applying to both of the devices at the same time.

Aux Contacts can be installed onto contactors either by front mounting, or side mounting. This is usually clear in the shape and size of the product, but please check the compatibility of your devices. Aux Contacts are really useful devices to aid in keeping an eye on the contactor.

You can, for example, hook up a low voltage LED directly to the Aux Contactor without having to worry about the overall voltage of the contactor it is linked to (as long the Aux Contactor is electrically isolated from the contactor) you could use the LED to monitor the device i.e. indicate if the motor is off/on.

Note

Tesys D side mount auxiliary contacts (662-6248, 744-6983, 400-1467, 400-1473) are not compatible with Tesys D DC Contactors.

Specificaties
Kenmerk Waarde
Series LAD8
12 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
12,41
(excl. BTW)
15,02
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 12,41
10 - 14
€ 12,03
15 +
€ 11,62
Related Products
The Automatic Recloser Auxiliary (ARA) performs automatic reclosing ...
Description:
The Automatic Recloser Auxiliary (ARA) performs automatic reclosing of the associated protection device after tripping, avoiding service interruptions.This range of Acti9 ARA auto reclosers increase the availability of installations without supervision, isolated, hard of access and demanding very great ...
Auxiliary contacts GV7-AE11 allow remote indication of the ...
Description:
Auxiliary contacts GV7-AE11 allow remote indication of the starter contact stateDifferent functions are perfomed according to the placement in the circuit breakerInsulation Voltage: 690AThermal Current: 6ATerminal covers for GV7 circuit breakers are available seperately.
TeSys GS switch-disconnector-fuses provide on-load breaking or making, ...
Description:
TeSys GS switch-disconnector-fuses provide on-load breaking or making, safe isolation and overcurrent protection of all low voltage electrical circuit. Can be used with NFC, DIN and BS fusesUpstream and downstream breaking of fuses for all ratingsConditional short-circuit withstand voltage of ...
Acti9 iACT Auxiliary Contactors are suitable for iCT ...
Description:
Acti9 iACT Auxiliary Contactors are suitable for iCT contactors, these auxiliaries allow different operations. iACTs allows indication or control of the "open"or "closed" position of the contactor power contactsiACTp is an interference suppressor which limits overvoltages on the control circuitiACTc ...