TF140DU Thermal Overload Relays

The TF140DU thermal overload relays are protection devices for the main circuit used mainly to protect motors in the event of overload or phase failure. These devices have trip class 10A.

Manual or automatic reset selectable
Phase loss sensitive
Two electrically isolated auxiliary contacts – 1 N.O. + 1 N.C.
TEST and STOP function – Trip indication on the front
Temperature compensation
Suitable for three- and single-phase applications

Specificaties
Kenmerk Waarde
FLC Motor Rating 110 A
Control Voltage 690 V ac
Contact Current Rating 6 (N.O) A, 10 (N.C) A
Pole Configuration 3P
Range AF Range
Contact Voltage Rating 440 V dc, 500 V ac
Mounting Style Under Contactor Mount
Supply Voltage 690 V ac
Series TF14
Normal State Configuration NO+NC
Number Of Auxiliary Contacts 2
Terminal Type Flat
Reset Method Automatic, Manual
Width 140mm
Length 89mm
Depth 126mm
Maximum Operating Temperature +55°C
Operating Temperature Range -25 +55 °C
Minimum Operating Temperature -25°C
4 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
187,00
(excl. BTW)
226,27
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 187,00
10 - 14
€ 179,42
15 +
€ 171,63
Related Products
Protects motor against overload and phase lossTrip class ...
Description:
Protects motor against overload and phase lossTrip class 10Auxiliary switch 1N/O and 1N/CStable, shock-resistant direct mounting on 100-K contactorBuilt in trip contact 95//96 and signal contact 97//98Auto/manual reset selectable on devicevisible trip indicationTest/trip actuatorStop actuator.
The DMPRs are available in standard and latching ...
Description:
The DMPRs are available in standard and latching versions and have the following features:. Supply voltage 115-230VacTrip and alarm contactsSuitable for load currents up to 200A using current transformersSupply warnings and trip indicationAuto/manual/local/remote resetTest facilityIndependently adjustable starting ...
The solid-state design of the 193-E1 Plus overload ...
Description:
The solid-state design of the 193-E1 Plus overload relay provides accurate, reliable and repeatable protection. A wide 5:1 adjustment range, dip switch (on EE versions) and isolated contacts provide application flexibility. The line-side over moulded power connections provides a sturdy ...
Manual or automatic re-settings availableDirect mounting on BF09 ...
Description:
Manual or automatic re-settings availableDirect mounting on BF09 - BF38 contactorsRated insulation voltage Ui: 690VFrequency limit 0-400HzOperating temperature -25 to +60°CCan be mounted on contactor or seperatelyTest button - trip indicator.