End Cap for use with 5ST3 7 MCB

  • RS-stocknr. 521-4636
  • Fabrikantnummer 5ST3750
  • Fabrikant Siemens
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

Series 5ST3 7 Bus-Bar System

With pin connections
Cut-to-length bar
For 1 or 3-phase line protective switches of the series 5SJ6 and 5SY
No additional connection terminal required for stranded connection up to 35mm²
Excellent accessibility for feeder cable
50→90A load at infeed single-sided/in-centre for 10mm²; 65→120A for 16mm²
Pin type connection
Material: Cu (10mm²); 16mm² fully insulated
Lug spacing: 18mm

Standards

DIN 57606, DIN 57659

Standards

DIN 57606, DIN 57659

Siemens Distribution Boards & Accessories

Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used.

Specificaties
Kenmerk Waarde
Accessory Type End Cap
For Use With 5ST3 7 MCB
Range Sentron
98 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
1,02
(excl. BTW)
1,23
(incl. BTW)
Aantal stuks
Per stuk
1 - 14
€ 1,02
15 - 24
€ 0,97
25 +
€ 0,96
Related Products
All CBEs have blade terminals and have an ...
Description:
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms). 1-pole magnetic hydraulic CBE with trip free snap action mechanism with toggle actuation.Industry standard dimensions with medium delay for most applications.Typically used on control equipment, communication ...
PCB, single hole mountingSub-miniature, double insulatedTrip free mechanismSlow ...
Description:
PCB, single hole mountingSub-miniature, double insulatedTrip free mechanismSlow response time (typically 30 seconds at twice nominal current rating) ideal for inductive/reactive loadsTypical life 5000 operations (0.5 to 3A)/1000 operations (4 and 5A) at twice nominal current ratingMainly for motors, transformers ...
A range of rugged, shock resistant IK10, modular ...
Description:
A range of rugged, shock resistant IK10, modular enclosure units with transparent horizontally hinged doors. For internal and external wall mounted applications. 4 module covers per row1 self adhesive label per rowDimensional stability from -20 to 115°CColour Grey RAL 7035. ...
Fill level monitoring by means of guided microwavesUpdated ...
Description:
Fill level monitoring by means of guided microwavesUpdated display of the current fill levelProgrammable hysteresis and window functionSimple operation via the user menuThe length of the sensor probe can be shortened as desiredAvailable probes 228 mm (RS order no. 488-047) ...