Tektronix TCP404XL Current Probe & Clamp

  • RS-stocknr. 499-598
  • Fabrikantnummer TCP404XL
  • Fabrikant Tektronix
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: US
Productomschrijving

TCP 312 / 404XL current probe

Bandwidth: 100 MHz (TCP 312), 2 MHz (TCP404XL)

Rise time: ≤3.5 ns (TCP 312), ≤175 ns (TCP404XL)
Signal delay: 17 ns (TCP 312), 103 ns (TCP404XL)
Max ACp-p: 60 A (TCP 312), 1414 A (TCP404XL)
Max direct current: 5 A → 1 A/V, 30 A → 10 A/V (TCP 312), 500 A → 1 A/mV (TCP404XL)
Current / div range: 1 A/V → 10 A/V (TCP 312), 1 A/mV (TCP404XL)
Impedance @ 1 MΩ: 0.08 Ω (TCP 312), 0.1 mΩ (TCP404XL)
Max voltage on exposed wire: insulated cable (TCP 312), 600 VRMS CAT I & II -
300 VRMS CAT III (TCP404XL)
Cable length: 1.5 m (TCP 312), 8 m (TCP404XL)

Tektronix Current Probe & Clamp

The Tektronix current probe is a split-core probe that uses both transformer and Hall Effect technology. When connected to Tektronix oscilloscopes with TEKPROBE level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC) interfaces, the probe makes current measurements and calculations simple and easy.

Features and Benefits

• Bandwidth is 2MHz DC
• Rise time is less than or equal to175 nanoseconds
• Automatic scaling and units
• Oscilloscope on-screen readout of magnitude and amps reduces measurement errors with no more hand calculations
• AC/DC input coupling
• Low insertion impedance reduces device under test loading
• Split-core construction allows easy circuit connection
• Status indicators provide visual operating status and notification of potential error conditions
• Degauss, probe open and overload not terminated into 50 O, noncompatible probe type
• Low DC drift and noise allows improved low-level current measurements
• 3rd party safety certification

Applications

• Development and analysis solutions for designers, installers, and service personnel in telecom, data communications, computer, and semiconductor power electronics environments
• Power supplies (switching and linear)
• Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
• Power inverters/converters
• Electronic ballasts
• Industrial/consumer electronics
• Mobile communications (phone, satellite, and relay stations)
• Motor drives
• Transportation systems (electronic vehicles, electric trains, locomotives, and avionics)

Certifications

• CAT I 600V
• CAT II 600V
• CAT III 300V
• CAT I
• CAT II
• CAT III

Specificaties
Kenmerk Waarde
Current 500A
Probe Type AC/DC
Minimum Bandwidth 0Hz
Maximum Bandwidth 2000kHz
Maximum Conductor Size 21 x 25mm
Safety Category CAT I 600 V, CAT II 600 V, CAT III 300 V
Series TCP
Safety Category Level CAT I, CAT II, CAT III
Model Number p TCP404XL
Best Accuracy ±1 %
Safety Category Voltage 300 V, 600 V
Bandwidth DC to 2 MHz
2 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
4.750,00
(excl. BTW)
5.747,50
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 4.750,00
Related Products
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
Suitable for use with oscilloscopes, recorders and data ...
Description:
Suitable for use with oscilloscopes, recorders and data loggers a.c. coupled output (no d.c. offset) Voltage output of 3V full scale for each range Fits around conductors up to 160mm diameter Extended battery life and external power supply input Meets ...