Current Probe & Clamp, With UKAS Calibration

Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: FR
Productomschrijving

Chauvin Arnoux MN60 Mini Clamps

Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.
Safe, non intrusive current measurement
40Hz to 10kHz bandwidth
Ergonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cable
Max. conductor size 20mm dia. or 20 x 5mm bus bar
Fitted with a 2m coaxial lead and 50Ω BNC plug to suit most analogue & digital oscilloscopes
Conforms to IEC1010-2-032 (safety standard) 600V Cat III

Specificaties
Kenmerk Waarde
Probe Type AC
Calibrated UKAS
Maximum Conductor Size 20mm
Safety Category CAT I V 300 V, CAT III 600 V
Safety Category Level CAT I, CAT III
Model Number p MN60
Best Accuracy ±1.5% + 5 mV
Safety Category Voltage 300 V, 600 V
Bandwidth 40 Hz → 40 kHz
1 op voorraad - levertijd is 1 werkdag(en) plus 1 dag extra in verband met gekalibreerd artikel. Gekalibreerde producten kunnen niet worden geretourneerd.
Prijs Each
311,00
(excl. BTW)
376,31
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 311,00
Related Products
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
Suitable for use with oscilloscopes, recorders and data ...
Description:
Suitable for use with oscilloscopes, recorders and data loggers a.c. coupled output (no d.c. offset) Voltage output of 3V full scale for each range Fits around conductors up to 160mm diameter Extended battery life and external power supply input Meets ...
Various bandwidths: DC to 50 MHz, 100 kHzDC ...
Description:
Various bandwidths: DC to 50 MHz, 100 kHzDC and AC measurementsSuperior accuracy and high signal to-noise ratioLow circuit insertion lossBattery powered with BNC connector or oscilloscope powered AutoProbe interface.
Superior measurement range from 100mA to 3000 Aac2000 ...
Description:
Superior measurement range from 100mA to 3000 Aac2000 Hours continuous battery life (two AA MN1500 LR6 alkaline batteries, not supplied)Low battery and range overload indicationRange selection by robust rotary switchHigh external field rejectionExcellent accuracy over full rangeSmall diameter (10mm) Rogowski ...