Fluke 2584888 Current Probe & Clamp

  • RS-stocknr. 645-3668
  • Fabrikantnummer I3000S FLEX-24
  • Fabrikant Fluke
Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: CN
Productomschrijving

i3000s Flex 24 Flexible 3000A a.c. Current Probe

Suitable for use with oscilloscopes, recorders and data loggers
a.c. coupled output (no d.c. offset)
Voltage output of 3V full scale for each range
Fits around conductors up to 160mm diameter
Extended battery life and external power supply input
Meets BS EN61010 – 1 Cat III 600V
Extended working temperature range -20°C to +90°C
Conforms to EN61010-1 CAT III 600V

Supplied with

2 x AA alkaline batteries, BNC to 4mm plug adaptor and operator's manual.

Specificaties
Kenmerk Waarde
Current 3000A
Probe Type AC
Minimum Bandwidth 10Hz
Maximum Bandwidth 50kHz
Maximum Conductor Size 178mm
Safety Category CAT III 600 V
Safety Category Level CAT III
Model Number p I3000S
Best Accuracy ±1 %
Safety Category Voltage 600V
Bandwidth 10 Hz → 50 kHz
4 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
5 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
506,00
(excl. BTW)
612,26
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 506,00
Related Products
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
Various bandwidths: DC to 50 MHz, 100 kHzDC ...
Description:
Various bandwidths: DC to 50 MHz, 100 kHzDC and AC measurementsSuperior accuracy and high signal to-noise ratioLow circuit insertion lossBattery powered with BNC connector or oscilloscope powered AutoProbe interface.