INA219AIDCNR Texas Instruments, Current Monitor Single Digital 8-Pin SOT-23

Datasheets
Wetgeving en compliance
Conform
Productomschrijving

Current Sense Power / Current Monitors, Texas Instruments

Current and power measurement for real-time system protection, feedback control and high-accuracy system monitoring.

Current Sensing Amplifiers have a voltage output that is proportional to the volt drop across a very low value resistor, usually in a high-current power rail. Hence they measure the current flowing in that power rail.

Specificaties
Kenmerk Waarde
Power Supply Type Single
Typical Single Supply Voltage 6 V
Minimum CMRR 100dB
Number of Channels per Chip 1
Output Type Digital
Maximum Supply Current 5 mA
Mounting Type Surface Mount
Package Type SOT-23
Pin Count 8
Dimensions 3 x 1.75 x 1.3mm
Height 1.3mm
Length 3mm
Maximum Operating Supply Voltage 5.5 V
Maximum Operating Temperature +125 °C
Minimum Operating Temperature -40 °C
Minimum Operating Supply Voltage 3 V
Width 1.75mm
15 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
330 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each (In a Pack of 5)
2,17
(excl. BTW)
2,63
(incl. BTW)
Aantal stuks
Per stuk
Per pak*
5 - 45
€ 2,17
€ 10,85
50 - 95
€ 1,71
€ 8,55
100 +
€ 1,368
€ 6,84
*prijsindicatie
Verpakkingsopties
Related Products
A range of operational amplifiers from Texas Instruments ...
Description:
A range of operational amplifiers from Texas Instruments designed for high-fidelity audio applications. The devices typically feature low levels of distortion and noise together with high slew rates and wide bandwidth. They are frequently able to operate over a wide ...
Current loop systems are used in electrically noisy ...
Description:
Current loop systems are used in electrically noisy industrial environments for sending analogue sensor data over long distances of 300m or more.
Current loop systems are used in electrically noisy ...
Description:
Current loop systems are used in electrically noisy industrial environments for sending analogue sensor data over long distances of 300m or more.
Current loop systems are used in electrically noisy ...
Description:
Current loop systems are used in electrically noisy industrial environments for sending analogue sensor data over long distances of 300m or more.