Phoenix Contact PSR-TBUS-TP Series DIN Plug Connector

Subtotaal (1 eenheid)*

€ 9,43

(excl. BTW)

€ 11,41

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 11 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 9,43

*prijsindicatie

RS-stocknr.:
666-7072
Fabrikantnummer:
2981716
Fabrikant:
Phoenix Contact
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Phoenix Contact

Product Type

DIN Plug Connector

Series

PSR-TBUS-TP

Hazardous Area Certification

No

Standards/Approvals

RoHS

Land van herkomst:
DE

Multi-application Modular System - PSR Series


The PSR safety relays from Phoenix contacts can be quickly and reliably assembled to form a tailor-made safety solution.

To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The Interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection.

Features and Benefits


• Quick system extension up to 10 modules, offering a safety system with up to 42 contacts

• Automatic identification of desired operating mode, no need to set switches or define parameters

• The system is based on a Master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains)

• Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple

• 24Vdc supply voltage

• Semiconductor output

• Depending on the wiring Safety category 2 or 4 can be maintained

• One or Two channel switches are used for control

Note

The device has a rear Interface for the DIN Rail connector T-BUS. Via this T-BUS Interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.