Schneider Electric 160VA Panel Mount Transformer, 215V ac, 230V ac, 245V ac Primary 1 x, 24V ac Secondary

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: CZ
Productomschrijving

ABT7ESM0 series economic transformer

This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applications.
ABT 7 series transformers provide enhanced electrical isolation between the mains supply and the application. The whole range features an electrostatic screen to limit the spread of electromagnetic interference and improve user safety.

Laminated Frame 230Vac Primary 75VA to 200VA (Multi Tapped)

Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Multi-hole frame fixing
Solder tag terminations
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Specificaties
Kenmerk Waarde
Primary Voltage Rating 215V ac, 230V ac, 245V ac
Secondary Voltage Rating 24V ac
Power Rating 160VA
Mounting Type Chassis
Number of Outputs 1
Length 97mm
Width 104mm
Depth 92mm
Dimensions 97 x 104 x 92mm
Minimum Operating Frequency 47Hz
Maximum Operating Frequency 63Hz
Minimum Temperature -20°C
Maximum Temperature +40°C
Weight 2.7kg
2 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
92,30
(excl. BTW)
111,68
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 92,30
10 - 24
€ 87,70
25 - 49
€ 81,56
50 - 99
€ 73,84
100 +
€ 64,62
Related Products
Brought to you by RS Pro, a range ...
Description:
Brought to you by RS Pro, a range of isolation transformers, performing in a single phase solution. Featuring screw connectors for multiple inputs and including robust brackets for screw and/or DIN Rail fixing. High quality isolation transformers are excellent within ...
This series of control transformers stands out thanks ...
Description:
This series of control transformers stands out thanks to the following special features:. Low voltage dropHigh performance during short-term operationInternational standard voltage 230 V/400 V in accordance with DIN IEC 38Primary-side ±5% taps to adjust the voltageCan be used worldwide ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Safety isolating transformer single phaseDIN rail mount (up ...
Description:
Safety isolating transformer single phaseDIN rail mount (up to 250VA) or Surface mount with screws (400VA & above) Terminals with finger protection IP2x or xxB up to 400VANew design provides interference filter between windingsClear laser engraved markingsSuitable for maximum 50°C ...