RS PRO 500VA Isolating Transformer, 230 V ac, 245 V ac, 400 V ac, 415 V ac Primary 1 x, 230V ac Secondary

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: PL
Productomschrijving

Control Panel Primary 230/ 400Vac with +15Vac Tap

High quality safety and isolating transformers designed for use in control circuits and general applications
Low loss noise laminations
Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility
Dual secondaries are centre tapped. Earth terminal provided
Varnish impregnated for overall protection against humidity and rusting
Fully shrouded cage clamp terminal with voltage markings
Detailed product specification on permanent label
High efficiency, low regulation design

Approvals

8888

Standards

BS EN 61558

Laminated

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230 V ac, 245 V ac, 400 V ac, 415 V ac
Secondary Voltage Rating 230V ac
Power Rating 500VA
Mounting Type Panel
Number of Outputs 1
Length 120mm
Width 143mm
Depth 130mm
Dimensions 120 x 143 x 130mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +35°C
Weight 7.5kg
Tijdelijk niet op voorraad – nieuwe voorraad verwacht op 25-03-2020, met een levertijd van 1 werkdag.
Prijs Each
135,44
(excl. BTW)
163,88
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 135,44
10 - 24
€ 112,69
25 - 49
€ 107,36
50 - 99
€ 102,63
100 +
€ 92,37
Related Products
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
This series of control transformers stands out thanks ...
Description:
This series of control transformers stands out thanks to the following special features:. Low voltage dropHigh performance during short-term operationInternational standard voltage 230 V/400 V in accordance with DIN IEC 38Primary-side ±5% taps to adjust the voltageCan be used worldwide ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.