RS PRO 50VA Isolating Transformer, 230V ac, 245V ac, 400V ac, 415V ac Primary 1 x, ±12V ac Secondary

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: PL
Productomschrijving

Control Panel Primary 230/ 400Vac with +15Vac Tap

High quality safety and isolating transformers designed for use in control circuits and general applications
Low loss noise laminations
Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility
Dual secondaries are centre tapped. Earth terminal provided
Varnish impregnated for overall protection against humidity and rusting
Fully shrouded cage clamp terminal with voltage markings
Detailed product specification on permanent label
High efficiency, low regulation design

Approvals

8888

Standards

BS EN 61558

Laminated

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac, 245V ac, 400V ac, 415V ac
Secondary Voltage Rating ±12V ac
Power Rating 50VA
Mounting Type Panel
Number of Outputs 1
Length 84mm
Width 84mm
Depth 91mm
Dimensions 84 x 84 x 91mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +35°C
Weight 1.9kg
16 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
27 op voorraad - levertijd is 2 werkdag(en) (UK-voorraad)
Prijs Each
42,15
(excl. BTW)
51,00
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 42,15
10 - 24
€ 36,30
25 - 49
€ 35,80
50 +
€ 32,93
Related Products
This range of covered (up to 320 VA) ...
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
High quality multi-purpose isolating transformers suitable for a ...
Description:
High quality multi-purpose isolating transformers suitable for a wide range of applications requiring selected secondary voltages. Panel mounting via the fixing holes Optional DIN rail mounting bracket for standard 35mm DIN rail (63 to 250VA units)Fully shrouded screw and push-on ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.