RS PRO 160VA Isolation Transformer, 15 → 400V ac Primary, 2 x 115V ac Secondary

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: PL
Productomschrijving

RS Pro Panel Isolation Transformers Single Phase

RS Pro high-quality panel isolation transformers are designed for use in general applications. These single phase transformers feature screw connectors for multiple input and brackets for screw fixing or for DIN Rails. They have a standard primary winding 0-230-400VAC with a +/- 15 V adjustment possibility around 0 and are 100% electrical and flash tested.

Features

High-quality safety and isolation transformers
Second section bobbin for full separation between primary and secondary winding
Low noise laminations
Earth terminal provided
High efficiency
Varnish impregnated

Specificaties
Kenmerk Waarde
Primary Voltage Rating 15 → 400V ac
Secondary Voltage Rating 2 x 115V ac
Power Rating 160VA
Mounting Type DIN Rail Mount, Screw Mount
Length 96mm
Width 89mm
Depth 110mm
Dimensions 96 x 89 x 110mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Weight 2.9kg
2 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
16 op voorraad - levertijd is 2 werkdag(en) (UK-voorraad)
Prijs Each
49,14
(excl. BTW)
59,46
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 49,14
Related Products
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Safety isolating transformer single phaseDIN rail mount (up ...
Description:
Safety isolating transformer single phaseDIN rail mount (up to 250VA) or Surface mount with screws (400VA & above) Terminals with finger protection IP2x or xxB up to 400VANew design provides interference filter between windingsClear laser engraved markingsSuitable for maximum 50°C ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.