Block 63VA DIN Rail Transformer, 230V ac, 400V ac Primary 2 x, ±110V ac, ±120V ac, ±55V ac, ±60V ac Secondary

  • RS-stocknr. 310-1695
  • Fabrikantnummer MIT/I/63
  • Fabrikant Block
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

Isolating Transformers : 0-230-400Vac Primary, 2x60-55-0-55-60Vac Secondary, DIN Mount

High quality multi-purpose isolating transformers suitable for a wide range of applications requiring selected secondary voltages.

Panel mounting via the fixing holes
Optional DIN rail mounting bracket for standard 35mm DIN rail (63 to 250VA units)
Fully shrouded screw and push-on crimp terminals with permanent marking
High efficiency, low regulation
Double reinforced insulation E (UL class 105)
4kV flash tested primary/secondary
Impregnated for protection against humidity
Insulation catagory Class E

Standards

EN61558

Approvals

VDE, UL recognised for Canada UL recognised

Approvals

VDE; UL

Standards

EN61558

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac, 400V ac
Secondary Voltage Rating ±110V ac, ±120V ac, ±55V ac, ±60V ac
Power Rating 63VA
Mounting Type DIN Rail
Number of Outputs 2
Length 72mm
Width 99mm
Depth 78mm
Dimensions 72 x 99 x 78mm
Maximum Temperature +40°C
Weight 1.3kg
Sorry, we konden onze voorraadniveaus nu niet controleren. Probeer de pagina te vernieuwen.
Prijs Each
71,79
(excl. BTW)
86,87
(incl. BTW)
Aantal stuks
Per stuk
1 - 24
€ 71,79
25 +
€ 68,15
Related Products
This series of control transformers stands out thanks ...
Description:
This series of control transformers stands out thanks to the following special features:. Low voltage dropHigh performance during short-term operationInternational standard voltage 230 V/400 V in accordance with DIN IEC 38Primary-side ±5% taps to adjust the voltageCan be used worldwide ...
This series of control transformers stands out thanks ...
Description:
This series of control transformers stands out thanks to the following special features:. Low voltage dropHigh performance during short-term operationInternational standard voltage 230 V/400 V in accordance with DIN IEC 38Primary-side ±5% taps to adjust the voltageCan be used worldwide ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.