Legrand 100VA DIN Rail Transformer, 230V ac, 400V ac Primary, 24V ac Secondary

  • RS-stocknr. 535-7733
  • Fabrikantnummer 0 442 33
  • Fabrikant Legrand
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: FR
Productomschrijving

Control Transformers

Safety isolating transformer single phase
DIN rail mount (up to 250VA) or Surface mount with screws (400VA & above)
Terminals with finger protection IP2x or xxB up to 400VA
New design provides interference filter between windings
Clear laser engraved markings
Suitable for maximum 50°C ambient, without de-rating

Standards

IEC 61-558-2-2 and 2-4 or 2-6

Supplied with

0V/earth connection link

Approvals

UL506, CSA

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac, 400V ac
Secondary Voltage Rating 24V ac
Power Rating 100VA
Mounting Type DIN Rail
Length 113mm
Width 94mm
Depth 94mm
Dimensions 113 x 94 x 94mm
Maximum Temperature +50°C
Weight 2kg
21 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
88 op voorraad - levertijd is 2 werkdag(en) (UK-voorraad)
Prijs Each
73,44
(excl. BTW)
88,86
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 73,44
10 - 24
€ 66,12
25 - 49
€ 65,18
50 - 99
€ 62,29
100 +
€ 59,17
Related Products
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided ...
High quality multi-purpose isolating transformers suitable for a ...
Description:
High quality multi-purpose isolating transformers suitable for a wide range of applications requiring selected secondary voltages. Panel mounting via the fixing holes Optional DIN rail mounting bracket for standard 35mm DIN rail (63 to 250VA units)Fully shrouded screw and push-on ...
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic ...
Description:
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic enclosureIntegrated fuse protection and thermal cut-out against overloading and short circuitsScrew-type terminals for the connecting leads on input and output sideMeet the requirements of IEC61 558, EN61 558, ...
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. Single-phase single-winding safety and isolation transformers.Able to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting.