Legrand 160VA DIN Rail Transformer, 230V ac, 400V ac Primary, 115V ac Secondary

  • RS-stocknr. 535-7812
  • Fabrikantnummer 0 442 64
  • Fabrikant Legrand
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: FR
Productomschrijving

Control Transformers

Safety isolating transformer single phase
DIN rail mount (up to 250VA) or Surface mount with screws (400VA & above)
Terminals with finger protection IP2x or xxB up to 400VA
New design provides interference filter between windings
Clear laser engraved markings
Suitable for maximum 50°C ambient, without de-rating

Standards

IEC 61-558-2-2 and 2-4 or 2-6

Supplied with

0V/earth connection link

Approvals

UL506, CSA

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac, 400V ac
Secondary Voltage Rating 115V ac
Power Rating 160VA
Mounting Type DIN Rail
Length 113mm
Width 94mm
Depth 112mm
Dimensions 113 x 94 x 112mm
Maximum Temperature +50°C
Weight 2.6kg
19 op voorraad - levertijd is 2 werkdag(en).
Prijs Each
88,88
(excl. BTW)
107,54
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 88,88
10 - 24
€ 79,94
25 - 49
€ 78,73
50 - 99
€ 75,25
100 +
€ 71,48
Related Products
This series of control transformers stands out thanks ...
Description:
This series of control transformers stands out thanks to the following special features:. Low voltage dropHigh performance during short-term operationInternational standard voltage 230 V/400 V in accordance with DIN IEC 38Primary-side ±5% taps to adjust the voltageCan be used worldwide ...
High quality multi-purpose isolating transformers suitable for a ...
Description:
High quality multi-purpose isolating transformers suitable for a wide range of applications requiring selected secondary voltages. Panel mounting via the fixing holes Optional DIN rail mounting bracket for standard 35mm DIN rail (63 to 250VA units)Fully shrouded screw and push-on ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.