CEAG Manual DOL Starter, 690 V ac, IP66

  • RS-stocknr. 248-5166
  • Fabrikantnummer GHG6351101R0108
  • Fabrikant CEAG
Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: DE
Productomschrijving

Motor Starter

Single-phase failure via thermal electromagnetic trips are featured in these circuit breakers/manual motor starters. The respective switch position is clearly indicated by the switch handle. Terminals are protected against accidental contact. They have a terminal cross section of up to 10mm² for the connection of single or multi-wire conductors. The external contours of the enclosure allow easy access to the connection terminals and easy installation.

Connection terminals accessible from all sides
IP66 to EN60529 rating
Isolating properties to DIN EN 60947-3
690Vac upto 25A rating
Single phase failure protection
Padlocking facility via red button
Clear indication of switch position
268mm x 140mm x 150mm (H/W/D)

Note

Short-circuit protection up to 100kA and maximum back-up see 'key characteristics' table

//media.rs-online.com/t_line/L248508-01.gif
Specificaties
Kenmerk Waarde
Motor Starter Type DOL
Voltage Rating 690 V ac
IP Rating IP66
Motor Starter Functionality Manual
Overall Length 225mm
Enclosure Yes
Overall Width 140mm
Overall Depth 156mm
Series GHG635
Hazardous Area Certification ATEX
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 20-08-2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
666,09
(excl. BTW)
805,97
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 666,09
Related Products
ABB MS165 series manual motor starters are compact ...
Description:
ABB MS165 series manual motor starters are compact and powerful for motor protection. The MS165 series features a clear indication of fault window to visible identification of short circuit tripping. Further features are a built-in disconnect function, temperature compensation, trip-free ...
Ideal to satisfy the basic protection requirements for ...
Description:
Ideal to satisfy the basic protection requirements for motor starters; thermal overload and short-circuit. Protection against overloads and short-circuitsProtection against phase failure and phase imbalanceProtection against insulation breaks (equipment protection only)Manual resetClass 10 for 3-phase motors.
The TeSys U is a modular system for ...
Description:
The TeSys U is a modular system for motor control; it enables the user to create a customised solution for their control requirements, from a series of standard modules. The plug-in modules allow the assembly and wiring before the selection ...
Motor direct starter in housingEasy assembly thanks to ...
Description:
Motor direct starter in housingEasy assembly thanks to pre-wiringShort circuit, motor overload and device protectionReady for connection, no additional overload relay requiredWith undervoltage release moduleSwitch settings: Hand - 0 - AutomaticCam switch for On/OffLockable main / EMERGENCY-STOP switchIn-situ or ...