ABB 2TLA020054R0300 Connection Block, For Use With Pluto Safety Controller

  • RS-stocknr. 733-2477
  • Fabrikantnummer 2TLA020054R0300
  • Fabrikant ABB
Datasheets
Wetgeving en compliance
Conform
Productomschrijving

Pluto Safety PLC, Base Unit

Pluto from ABB is an "All-Master" safety PLC concept, which simplifies the design of safety systems and achieves the highest safety category 4 according to EN 954-1. All Pluto's are Master units and can see the other Pluto's inputs, outputs and global memories. This enables the Pluto to evaluate the information from the other Pluto's and then take decisions concerning its own safety devices. The Gateway units are available for several different bus systems, i.e. Profibus (733-4836), CanOpen (733-4830), Devicenet (733-4849) and Ethernet (733-4842). Of Pluto's inputs (the smallest unit has 16 I/O), thus can be configured as either inputs or outputs. In the Pluto family by ABB most modules have dual safety outputs - potential free or PNP types. In a two-wire bus system up to 32 Pluto units can be safely connected and communicate with a superior system via a Gateway or HMI displays. Therefore within a maximum extended system 1472 I/O's can be connected. Also all input components may be connected in series for even more complexity and optimisation.

Simple and easy programming facilities
Easy to configure and install
Up to 640 I/O's
Multiple Plutos can be connected on a bus (via using the IDFIX identifier) and then further interfaced with external networks by using a Gateway, typical example RS stock number (733-4842)
High safety level
Free software available
Programming over the bus
35 mm DIN rail mounting
The IDFIX (733-4824) is an identification circuit which allows multiple Plutos to be identified when connected on a bus system. This module is available to distribute a PLC program within a network of Pluto devices.
Tina adapters such as (733-2477) can be used to connect external safety monitoring equipment

Note

The IDFIX device (733-4824) is connected between the input terminals ID and 0V (also note that the IDFIX device is not required when using a single Pluto, however the absense of an IDFIX requires to be stated when programming the Pluto device.)

Approvals

TUV, FS, CSA

Standards

European Machinery Directive 2006/42/EC
EN ISO 12100-1, EN ISO 12100-2,
EN 60204-1, EN 954-1, EN ISO 13849-1,
EN 62061

Specificaties
Kenmerk Waarde
Accessory Type Connection Block
For Use With Pluto Safety Controller
Connector Size M12 5-pin
3 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
13 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
151,47
(excl. BTW)
183,28
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 151,47
10 - 14
€ 145,27
15 +
€ 138,92
Related Products
Configurable device capable of centralised monitoring of multiple ...
Description:
Configurable device capable of centralised monitoring of multiple safety functions such as E-stops, safety interlocks, magnetic safety interlocks, two hand controllers, light curtains, zero speed detection, enabling switches. Designed to provide a solution for safety applications requiring conformity to category ...
Telemecanique safety light curtains from the XUSL Series. ...
Description:
Telemecanique safety light curtains from the XUSL Series. Typical applications would include robotic systems, assembly and packaging lines, welding equipment and machine tools. All models are highly reliable and excellent quality. Straight or angles detectionPre-wired connectorsMetal collarIP65/67/69K rated.
Telemecanique safety light curtains from the XUSL Series. ...
Description:
Telemecanique safety light curtains from the XUSL Series. Typical applications would include robotic systems, assembly and packaging lines, welding equipment and machine tools. All models are highly reliable and excellent quality. Straight or angles detectionPre-wired connectorsMetal collarIP65/67/69K rated.
3 positive opening contacts as standard, on guard ...
Description:
3 positive opening contacts as standard, on guard openingHead rotates in 90° steps giving 8 actuator entry pointsMinimum operating force for positive opening: 15NIngress protection IP672 x cable entries tapped M16 x 1.5 ISO or PG11Actuator needs ordering separately (see ...