Eaton xEffect 10 A MCB Mini Circuit Breaker, 2P<NEWLINE> Curve S

  • RS-stocknr. 532-5152
  • Fabrikantnummer 278810 & FAZ-S10/2
  • Fabrikant Eaton
Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: AU
Productomschrijving

Eaton FAZ Series MCBs

Eaton FAZ- miniature circuit breakers are Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit, Trip-free design. Breaker cannot be defeated by holding the handle in the ON position

Features and Benefits

Thermal-magnetic overcurrent protection
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm

Standards

IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).

Q: What is the differences in the Tripping Curves B, C, D and S?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Curve S Tripping 13 to 17 times the rated current
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies

Standards

IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2

Standards

IEC/EN60947-2

Specificaties
Kenmerk Waarde
Range XEffect
Series FAZ
Number of Poles 2
Current Rating 10 A
Tripping Characteristics Type S
Rated AC Voltage 230 V
Breaking Capacity 10 kA
Length 80mm
Width 35mm
Depth 73.5mm
6 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
Was € 36,33
33,21
(excl. BTW)
40,18
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 33,21
10 - 14
€ 32,29
15 +
€ 31,42
Related Products
MEM 250V DIN rail mount RCD’s and MCB’s ...
Description:
MEM 250V DIN rail mount RCD’s and MCB’s etc, for use as spares and replacements in Memera consumer units. Complies with BS EN 60898Accept cable up to 25mm²Thermal/magnetic operationPositive contact indication (red-on, green-off)1, 2 or 3 pole.
Type K characteristics have been specifically designed for ...
Description:
Type K characteristics have been specifically designed for the protection of motor control circuits and items used within them. It has a very sensitive thermal curve, combined with a magnetic setting of 8 times the normal input current (In), which ...
Type D characteristic offers short circuit response (but ...
Description:
Type D characteristic offers short circuit response (but greater than Type C) of 10-13 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance ...
The FAZ series by Eaton offers a wide ...
Description:
The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eaton’s FAZ DIN rail mountable circuit breaker is designed for use in control panel applications. • The Eaton miniature circuit breaker has a ...