Schneider Electric Acti 9 iC60N MCB Mini Circuit Breaker 2P, 1 A, 6 kA, Curve C

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: FR
Productomschrijving

Schneider Electric Acti9 i60N MCBs 2 Pole

Acti 9 iC60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.

VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime

Benefits and Features

Downstream circuit is always safe
Class insulation ensures continuous protection for both operators and unqualified persons.
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening
Provide greater continuity of service thanks to VisiTrip.
Double clip dismounting with comb busbar in place

Standards

IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCB’s).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).

Q: What is the differences in the Tripping Curves B, C, and D?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors

Merlin Gerin – MCBs

Miniature Circuit Breakers; Contact Position indicated by switch levers

Specificaties
Kenmerk Waarde
Range Acti 9
Series iC60N
Number of Poles 2
Current Rating 1 A
Tripping Characteristics Type C
Rated AC Voltage 12 → 60 V, 100 → 130 V, 220 → 240 V, 380 → 415 V, 400 V, 440 V
Rated DC Voltage 12 → 144V
Breaking Capacity 6 kA
34 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
103,20
(excl. BTW)
124,87
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 103,20
10 - 14
€ 99,01
15 +
€ 94,71
Related Products
SMISSLINE line safety switches with high rated switching ...
Description:
SMISSLINE line safety switches with high rated switching capacityPluggable in any positionFree selection and display of contacting phases (1-pole versions)Pole conductor contacting (L1, L2, L3) visible through inspection windowContact position display visible through inspection windowWith integrated input ...
Allen Bradley general purpose MCBs from the 1492 ...
Description:
Allen Bradley general purpose MCBs from the 1492 SP series. The MCBs have a Type D tripping characteristic and an instantaneous break time. 1, 2 or 3 pole versions available. All the MCBs incorporate screw terminals and can be DIN ...
Line protective switches with quick plug in terminalsMainly ...
Description:
Line protective switches with quick plug in terminalsMainly used to protect socket outlet and lighting circuits with rated currents from 10 to 63 ADIN rail assemblyTouch protection to VBG4 / BGV A2Rated voltage: 1P - 230/400Vac; 1P+N - 230Vac; 2P/3P+N/4P ...
MCCB that allow use of supply busbars and ...
Description:
MCCB that allow use of supply busbars and auxiliary contact. 10 kA Breaking capacity (230 Vac : 25 kA)C type : Detect C components faultsConnection type : Screw / ScrewTwo modules.