ABB Manual 3P Motor Protection Circuit Breaker, 690 V ac, 1, 3 Phase, IP20

  • RS-stocknr. 445-0364
  • Fabrikantnummer MS116-4.0
  • Fabrikant ABB
Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: DE
Productomschrijving

Starters

Covers motors up to 16A (7.5kW)
Local isolator
Protects against overloads, short circuits, phase failure and faults in cabling or wiring
These Motor Starters can be used in conjunction with ABB Contactors, stock no. 445-0897 typically
Accessories available from auxiliary/signal contacts to under voltage releases. Using an adaptor, motor starter combinations can be easily formed utilising contactors from ABB's mini and A series range; see typically 445-0897 and 445-0825

Standards

IEC 60 947-1/IEC 60 947-2/EN60 P47-1/EN60 (47-2)

Approvals

UL, CSA

//media.rs-online.com/t_line/LF445029-02.gif
Specificaties
Kenmerk Waarde
Number of Poles 3P
Voltage Rating 690 V ac
Series MS116
3 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
5 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
65,00
(excl. BTW)
78,65
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 65,00
Related Products
The ABB MS132 series of manual motor starters ...
Description:
The ABB MS132 series of manual motor starters are compact highly reliable devices used to manually switch on and off motors. The MS132 series protects the motors reliably, without the need for a fuse, from short-circuits, overload and phase failures. ...
Eaton's reliable and robust motor protection circuit breakers ...
Description:
Eaton's reliable and robust motor protection circuit breakers are the perfect solution for protecting your motors from faults such as an overload of high voltages, short circuits or relay shutdowns. Down-time of machinery can be detrimental to a business and ...
DIN rail mounted, mechanically reset protection devices.Transformer short ...
Description:
DIN rail mounted, mechanically reset protection devices.Transformer short circuit and overload protectionThe short circuit release is set to 20 x Iu, so even transformers that have high inrush currents have protectionRotary handle for ease of trip indication after a fault ...
Modular Motor Protective Circuit Breakers designed for use ...
Description:
Modular Motor Protective Circuit Breakers designed for use with add-on contactor modules and accessories (see below) which provide isolation, short circuit and thermal protection. The units are DIN-rail mounting and part of the xStart family of control gear products, and ...