12V ac 2 Output Through Hole PCB Transformer, 24VA

  • RS-stocknr. 170-7374
  • Fabrikantnummer FL 24/12
  • Fabrikant Block
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

PCB Mounting Low Profile 115 / 230Vac Primary

Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Standards

VD 61 558

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 12V ac
Power Rating 24VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 68mm
Width 31.4mm
Depth 57mm
Dimensions 68 x 31.4 x 57mm
Weight 445g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
40 op voorraad - levertijd is 2 werkdag(en).
Prijs Each (In a Tray of 20)
13,012
(excl. BTW)
15,745
(incl. BTW)
Aantal stuks
Per stuk
Per tray*
20 +
€ 13,012
€ 260,24
*prijsindicatie
Related Products
RS Pro high-quality panel isolation transformers are designed ...
Description:
RS Pro high-quality panel isolation transformers are designed for use in general applications. These single phase transformers feature screw connectors for multiple input and brackets for screw fixing or for DIN Rails. They have a standard primary winding 0-230-400VAC with ...
Brought to you under the trusted RS Brand, ...
Description:
Brought to you under the trusted RS Brand, these single phase isolation transformers are DIN Rail mountable. Fully encapsulated in a moulded resin case, these high quality safety and isolation transformers are intended for use in general applications. • Single ...
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings ...
Description:
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedHigh efficiency and ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.