Parker 3 → 8bar 0.1 → 30s Pneumatic Timer, -15 → +60°C

  • RS-stocknr. 410-488
  • Fabrikantnummer PRT-C10
  • Fabrikant Parker
Datasheets
Wetgeving en compliance
Conform
Productomschrijving

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Very Reliable
Long Life Expectancy

Note

All logic units require mounting on a separate 2 or 3 port base, available separately. Logic units have an input (green) and output (red) pressure indicator to show the state of the respective signal. Units are supplied with two captive screws for mounting on all types of base and sealing o-rings are in the bottom of each unit.

//media.rs-online.com/t_line/L267136-01.gif
//media.rs-online.com/t_line/L267136-02.gif
//media.rs-online.com/t_line/L267136-03.gif
//media.rs-online.com/t_line/L267137-01.gif

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Specificaties
Kenmerk Waarde
Manufacturer Series PRT
Minimum Operating Pressure 3bar
Maximum Operating Pressure 8 bar
Minimum Operating Temperature -15°C
Maximum Operating Temperature +60°C
Minimum Time 0.1s
Maximum Time 30s
6 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
13 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
113,73
(excl. BTW)
137,61
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
€ 113,73
5 +
€ 110,26
Related Products
Combination of adjustable orifice and fixed flow allows ...
Description:
Combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Bracket and Panel mounting.
An adjustable single impulse generator which transforms a ...
Description:
An adjustable single impulse generator which transforms a maintained signal into a single pulse of adjustable durationWhen an input signal is applied the output is switched on via the negative output relay. At the same time the reservoir starts to ...
Provides an adjustable time delay between successive operations ...
Description:
Provides an adjustable time delay between successive operations in a sequence. Ideal for use in hazardous environments.Automatic reset.
Fitted between a trip valve and directional control ...
Description:
Fitted between a trip valve and directional control valve when it is necessary to eliminate a trapped or locked pilot signal that would otherwise prevent the control valve from resetting. When an input signal is applied, it generates a short ...