Fluke 434 Power Quality Analyser RS Calibration

  • RS-stocknr. 749-3027
  • Fabrikantnummer FLUKE-434-II
  • Fabrikant Fluke
Datasheets
Wetgeving en compliance
Vrijgesteld
Land van herkomst: NL
Productomschrijving

Fluke 434 Series II; 435 Series II; 437 Series II 3-Phase Power Quality Analyser

The new Fluke 430 Series II Three-Phase Power Quality and Energy Analysers provide you with more detailed power quality analysis capability, and a new Fluke-patented energy monetization function.

The Fluke 434 Series II and 435 Series II offer the best in power quality analysis and introduce, for the first time ever, the ability to monetarily quantify energy losses. The new Fluke 434, 435 and 437 Series II models help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems. Additionally, the Fluke-patented energy loss algorithm, Unified Power Measurement, measures and quantifies energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.

Features & Benefits

• Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses. • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
• Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
• Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places.
• Automatic trending: Every measurement is always automatically recorded, without any set-up.
• System-monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
• Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
• View graphs and generate reports: With included analysis software.
• Battery life: Seven hours operating time per charge on Li-ion battery pack.
• Wireless data download: Download data to PC wirelessly and capture screens using Fluke Connect® App.
• Energy monetization – calculate the fiscal cost of energy waste due to poor power quality
• Energy assessment – quantify the before and after installation improvements in energy consumption to justify energy saving devices
• Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online
• Predictive maintenance – detect and prevent power quality issues before they cause downtime
• Long-term analysis – uncover hard-to-find or intermittent issues
• Load studies – verify electrical system capacity before adding loads"

Supplied with

All models are supplied with the TL430 test lead and alligator clip set, WC 100 colour coding clips and regional decals, 4 x i430 thin flexi current probes, BP290 battery, BC430 power adapter with international power adapter set, USB cable A-B mini, PowerLog on CD (including operator manuals in PDF format, 8GB SD card. C1470 soft case (for 434 II and 435 II) and C437 hard case with rollers for the 437 II.

Fluke Three-phase Power Quality and Energy Analyser

The Fluke three-phase power quality and energy analyser help to locate, predict, prevent and troubleshoot power quality problems in three-phase and single-phase power distribution systems. The Fluke-patented energy loss algorithm, unified power measurement, measures and quantifies energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.
Supplied with:
All the models are supplied with the TL430 test lead and alligator clip set, WC 100 colour coding clips and regional decals, 4 x i430 thin Flexi current probes, BP290 battery, BC430 power adapter with international power adapter set, USB cable A-B mini, PowerLog on CD (including operator manuals in PDF format, 8GB SD card. C1470 soft case (for 434 II and 435 II) and C437 hard case with rollers for the 437 II.

Features and Benefits

• Current measurement is 6000A
• Power measurement is 6000W
• Voltage measurement is 1000V
• Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses
• Troubleshoot real-time: Analyse the trends using the cursors and zoom tools
• Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places
• Automatic trending: Every measurement is always automatically recorded, without any set-up
• System-monitor: Ten power quality parameters on one screen according to EN50160 power quality standard
• Logger function: Configure for any test condition with memory for up to 600 parameters at user-defined intervals
• View graphs and generate reports: With included analysis software
• Battery life: Seven hours operating time per charge on Li-ion battery pack
• Energy monetization – calculate the fiscal cost of energy waste due to poor power quality
• Energy assessment – quantify the before and after installation improvements in energy consumption to justify energy saving devices
• Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online
• Predictive maintenance – detect and prevent power quality issues before they cause downtime
• Long-term analysis – uncover hard-to-find or intermittent issues
• Load studies – verify electrical system capacity before adding loads

Certifications

• 600V CAT IV/1000V CAT II safety rated
• IEC 61000-4-30 Class S
• IEC61000-4-7
• EN50160
• EN61326

Specificaties
Kenmerk Waarde
Absolute Maximum Current Measurement 6000A ac
Absolute Maximum Power Measurement 6kVA
Number of Phases 3
Maximum Voltage 1000V ac
Best Voltage Measurement Accuracy ±0.5 %
Best Current Measurement Accuracy ±0.5% + 5 Digits
Display Type LCD
Calibrated RSCAL
Measurement Type Current, Flicker, Frequency, Harmonics, Inrush Current, Inrush Duration, Kilowatt Hour, Power Factor, Unbalance, Voltage, Watt
Measurement Standards EN50160, EN61326
Interface Type RS232, USB
Memory Capacity 8GB
Power Source Battery
Battery Type Rechargeable Lithium-Ion
Battery Life 8 h
Minimum Operating Temperature 0°C
Maximum Frequency 57.5 (50 Hz) Hz, 69 (60 Hz) Hz
Model Number p 434
Height 70mm
Weight 2kg
Maximum Operating Temperature +40°C
Length 265mm
Dimensions 265 x 190 x 70mm
Width 190mm
Minimum Frequency 42.5 (50 Hz) Hz, 51 (60 Hz) Hz
1 op voorraad - levertijd is 1 werkdag(en) plus 1 dag extra in verband met gekalibreerd artikel. Gekalibreerde producten kunnen niet worden geretourneerd.
Prijs Each
4.893,00
(excl. BTW)
5.920,53
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 4.893,00
Related Products
Fluke offers an extensive range of power quality ...
Description:
Fluke offers an extensive range of power quality test tools for troubleshooting, preventive maintenance, and long-term recording and analysis in industrial, utilities and commercial building applications. Product overview: Fluke 1730-TL2M Test Lead Set2 m test lead for connecting measurement input ...
Teledyne LeCroy's Power Analyzer Package provides exceptional ability ...
Description:
Teledyne LeCroy's Power Analyzer Package provides exceptional ability to measure and analyze the operating characteristics of power conversion circuits. Critical power switching device measurements, control loop modulation analysis, and line power harmonic testing are all simplified with a dedicated user ...
The 6813C AC power source/analyser from Keysight is ...
Description:
The 6813C AC power source/analyser from Keysight is a performance AC test soloution with 1750 VA maximum output power and a built in arbitrary waveform generator. 20 Vrms test signal (Option 001)High-speed measurements: 5.6 ms201 points list sweepVersatile PC connectivity ...
The HM6050-2 line impedance stabilization network (LISN) is ...
Description:
The HM6050-2 line impedance stabilization network (LISN) is basically a filter network. Measurement of Line-conducted Interference within the Range from 9kHz…30MHz (CISPR 16)Selectable Transient LimiterArtificial Hand Connector A lowpass filter connects the DUT to the AC power lines.The LISN presents ...