Telemecanique Sensors Air, Corrosive Fluid, Fresh Water, Hydraulic Oil, Sea Water Pressure Switch, Analogue 0 →

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: CH
Productomschrijving

OsiSense XMLG Electronic Pressure Sensors

Schneider Electric XMLG pressure transmitters and pressure switches feature a ceramic pressure measuring cell. The deformation caused by the pressure is transmitted to the resistors of a Wheatstone bridge silk-screened on the ceramic. The change in resistance is then processed by the integrated electronics, providing either a digital or analog output signal.

Adjustable differential
1 CO snap acting contact
Temperature range: –15 to +85 °C
Enclosure rating: IP66

Specificaties
Kenmerk Waarde
Minimum Pressure Reading 0bar
Maximum Pressure Reading 10bar
Accuracy ±0.1 %
Output Type Analogue
Media Measured Air, Corrosive Fluid, Fresh Water, Hydraulic Oil, Sea Water
Analogue Output 0 → 10 V
Electrical Connection M12 3-Pin Connector
Response Time 2 ms
Maximum Current 20 mA
Supply Voltage 24 V dc
Housing Material Aluminium Oxide Ceramic, Stainless Steel
IP Rating IP66, IP67
Maximum Operating Temperature +85°C
Minimum Operating Temperature -15°C
Mounting Type Thread Mount
1 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
238,00
(excl. BTW)
287,98
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 238,00
Related Products
Osisense XMP pressure sensors are for control circuits ...
Description:
Osisense XMP pressure sensors are for control circuits and are used to control the pressure of water (sea and fresh) and air. XMP series pressure sensors have an adjustable differential and are for regulation between two thresholds. Diaphragm pressure actuatorG ...
Schneider Electric XMLA pressure switches for control circuits ...
Description:
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are ...
Schneider Electric XMLB pressure switches for control circuits ...
Description:
Schneider Electric XMLB pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLB pressure and vacuum switches have an adjustable differential and are ...
Telemecanique OsiSense XMLP high precision pressures transmitters suitable ...
Description:
Telemecanique OsiSense XMLP high precision pressures transmitters suitable for use within various industrial applications that need pressure control and regulation. These compact pressure sensors are easy and flexible to mount, reducing time and effort needed to install. The stainless steel ...