Telemecanique Sensors Air, Hydraulic Oil, Non-Corrosive Gas, Non-Corrosive Liquids Differential Pressure Switch

Datasheets
Wetgeving en compliance
Conform
Productomschrijving

9012 GAW Diaphragm Low Pressure Adjustable

The 9012G single stage pressure switches are control circuit rated devices. This series of switches can be used in pneumatic and hydraulic systems and on a variety of machine and process applications to protect the equipment. These pressure switches can be used to either control or monitor the system pressure.

Diaphragm actuated
Buna-N Nitrile diaphragm, zinc plated steel housing

Standards

UL, CSA

Specificaties
Kenmerk Waarde
Pressure Range 3 → 150 (Decreasing) psi, 6 → 30 (Differential) psi
Pressure Reading Type Differential
Media Measured Air, Hydraulic Oil, Non-Corrosive Gas, Non-Corrosive Liquids
Output Type SPDT-NO/NC
Supply Voltage 240 V ac, 250 V dc
Minimum Pressure Reading 3 (Decreasing) psi, 6 (Differential) psi
Maximum Pressure Reading 30 (Differential) psi, 150 (Decreasing) psi
Process Connection 0.25 in NPTF
Electrical Connection 0.5 in NPT
Minimum Operating Temperature -10°F
Maximum Operating Temperature +85°F
Accuracy <4 (Repeat) %
Maximum Current 6 A
Housing Material Die Cast Aluminium Alloy 380
Mounting Type Cable Mount
5 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
396,45
(excl. BTW)
479,70
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 396,45
Related Products
Schneider Electric XMLA pressure switches for control circuits ...
Description:
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are ...
Osisense XMP pressure sensors are for control circuits ...
Description:
Osisense XMP pressure sensors are for control circuits and are used to control the pressure of water (sea and fresh) and air. XMP series pressure sensors have an adjustable differential and are for regulation between two thresholds. Diaphragm pressure actuatorG ...
Schneider Electric XMLA pressure switches for control circuits ...
Description:
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are ...
Schneider Electric XMLB pressure switches for control circuits ...
Description:
Schneider Electric XMLB pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLB pressure and vacuum switches have an adjustable differential and are ...