Cynergy3 Process Pump Controller, 250 V ac, IP21

  • RS-stocknr. 348-7977
  • Fabrikantnummer FCTE45
  • Fabrikant Cynergy3
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: IT
Productomschrijving

Pump Protection Switch

Fits to pump body or pipe work (pipe diameter 20 to 200mm)
A rapid rise past the set-point temperature of 45°C (if the inlet water level falls below the centre line of the inlet) of any centrifugal type pump, will cause this device to react.
High power switch cuts off the electrical supply to protect the pump from dry running, seal overheating and other damage
Switch rating: 16A/250V ac
Manual reset restarts the pump
Condition indicator light
Dimensions; H46mm, W46mm, L72mm

Specificaties
Kenmerk Waarde
Supply Voltage 250 V ac
IP Rating IP21
Maximum Fluid Temperature +45°C
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 25-09-2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
35,11
(excl. BTW)
42,48
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
€ 35,11
5 - 9
€ 34,01
10 +
€ 32,91
Related Products
Fully Automatic operation enabling both draining and filling ...
Description:
Fully Automatic operation enabling both draining and filling at the same time with a single device Protects submersible pumps against dry running and prevents overfilling Enables maximum utilization of incoming liquid supply Specially designed corrosion and shock resistant sensors to ...
Flowline's general purpose range of level controller displays ...
Description:
Flowline's general purpose range of level controller displays which cover an assortment of engineering units. Comes equipped with either a 4-20mA or 0-10mA level sensor inputs, with various configurations to ensure your application is covered. Optional 2 or 4 programmable ...
Pump control, Alternating/parallel. Alternated access of two pumps ...
Description:
Pump control, Alternating/parallel. Alternated access of two pumps or other devicesEven distribution of dutyParallel duty at high demand Operation using 1 or 2 input signals (two modes of operation)Timing offset of the two loads to avoid water hammer effcectsSupply voltage ...
Features a differential pressure switch, dry running cut-out, ...
Description:
Features a differential pressure switch, dry running cut-out, control panel, pressure reservoir and non-return valveStart up pressure 0.5 to 3.5 bar minimum, adjustableDifferential pressure switch controls water pressure in pumped systems and ensures constant flowHelps to prevent boiler cycling and ...