2P 40 A, Instantaneous RCD Switch, Trip Sensitivity 30mA, DIN Rail Sentron 5SV3

  • RS-stocknr. 124-7729
  • Fabrikantnummer 5SV3314-6
  • Fabrikant Siemens
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

Series 5SV3 RCCBs

From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality.

Residual current operated circuit breaker for personnel and fire protection
Silicone free
2 or 4 pole versions available
Instant tripping, surge current withstand capability >1kA
DIN rail mounting
Equipment life span: >10,000 switching cycles
Enclosure: IP20
Ambient temperature: -25→+45 °C
Break time - instantaneous
Protection against residual currents
Easy and safe installation

Specificaties
Kenmerk Waarde
Number of Poles 2
Current Rating 40 A
Trip Sensitivity 30mA
Rated AC Voltage 230 V ac
Mounting Style DIN Rail
Range Sentron
Break Time Instantaneous
Series 5SV3
Overall Length 35.8mm
Overall Width 77.2mm
Terminal Contact Type Screw
Overall Dimensions 35.8 x 77.2 x 89.8mm
Overall Depth 89.8mm
Tripping Characteristics Type A
Reset Actuator Type Toggle Switch
Application Industrial, Non-Residential, Residential
Circuit Breaker Type RCCB
8 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
114,30
(excl. BTW)
138,30
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 114,30
Related Products
New generation of Type 3 'MNT' surge protection ...
Description:
New generation of Type 3 'MNT' surge protection that provides high levels of safety. Protection that plugs into the mains socket for all devices supplied by the 230 V network.The MNT-TV-SAT B/F model is designed for audiovisual devices, and offers ...
Complete surge protector for analogue telecommunication interface surge ...
Description:
Complete surge protector for analogue telecommunication interface surge protection.Comprising a socket and a connector, the latter may be unplugged without causing system outage, thereby allowing easy maintenance.For mounting on DIN rail.Screw connection.
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...
Acti 9 iPRD DIN rail Surge Protector Devices ...
Description:
Acti 9 iPRD DIN rail Surge Protector Devices are geared to absolute safety and improved continuity of service. Maximum discharge current 8 to 65 kA Integrated disconnector for short-circuit current withstand, Isc, up to 25 kAMaximum steady state voltage, Uc ...