Siemens 4 Pole Type B Residual Current Circuit Breaker, 25A 5SM3, 300mA

  • RS-stocknr. 621-9957
  • Fabrikantnummer 5SM3642-4
  • Fabrikant Siemens
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

Series 5SM3, Type B SEQUENCE, 4-pole

All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currents
Increased operating reliability in networks with capacitive impedances based on adapted actuation characteristic
Switch handle and test button may be locked via handle lock
Time-delayed disconnect function in the event of transient stray currents
High current capacity < 3 kA

Applications:

Systems with consumers in which smooth residual DC currents may also occur
Use in three-phase systems

Standards

IEC / EN 61008-1, IEC / EN / 61543

Approvals

VDE 0664 Part 10, VDE 0664 Part 100, VDE 0664 Part 30

Siemens FI circuit breaker

Specificaties
Kenmerk Waarde
Current Rating 25A
Number of Poles 4
Range Sentron
Trip Sensitivity 300mA
Tripping Characteristics Type B
Voltage Rating 400V
Series 5SM3
2 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
Was € 850,00
787,50
(excl. BTW)
952,88
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 787,50
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
RCCB for alternating and pulsating DC residual currentsOption ...
Description:
RCCB for alternating and pulsating DC residual currentsOption for power connection from above or belowTunnel terminals with wire protection on both sidesCombination terminal at the bottom for simultaneous connection of busbars and conductorsSafe for fingers and overhands according to DIN ...
Compact and functional designThe new F200 B RCCBs ...
Description:
Compact and functional designThe new F200 B RCCBs feature an innovative design that makes the products compact. Indeed, the two-pole device is the first one on the market that is built in just two modules and its compact dimensions ensure ...