Schneider Electric 4P Pole Residential RCCBs, 25A iID, 30mA

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: FR
Productomschrijving

RCCB Acti9 iID

The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service.

iID residual current circuit breakers AC Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 100 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).

iID residual current circuit breakers Asi Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 300 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
Increased immunity from electrical interference and polluted or corrosive environments.

Specificaties
Kenmerk Waarde
Current Rating 25A
Range Acti 9
Number of Poles 4P
Trip Sensitivity 30mA
Series iID
Break Time Instantaneous
Rated AC Voltage 415V
Mounting Style DIN Rail Mount
2 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
2 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
181,82
(excl. BTW)
220,00
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 181,82
Related Products
These devices complement our range of MK Series ...
Description:
These devices complement our range of MK Series enclosures. Manufactured to BS EN 608986kA breaking capacityType B (59xxS series) and type C (87xxS series) versions availableProvides positive contact indication in accordance with IEE 16th edition wiring regulationsThermal magnetic operation provides ...
This range of MCB's are suitable for fitting ...
Description:
This range of MCB's are suitable for fitting into consumer units, they have been fully tested and conform to the relevant standards to ensure safety, protection and reliability. From 6A to 63ATerminal capacity: 1mm2 to 25mm2Operating temperature -5° to 40°C35mm ...
All CBEs have blade terminals and have an ...
Description:
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms). Flush-mount circuit breaker models to protect apparatus.Valued for their thermal protection of small electronic assemblies.Front panel mount.Fuse holder type.Resettable.
The ABB F200 series residual current circuit breaker ...
Description:
The ABB F200 series residual current circuit breaker is a 2-pole type B device. It has an electrical rating of 230V and 63A. The operation of the residual circuit breaker is indicated using a green LED. This circuit can operate ...