Europa 2 Pole Type AC Residual Current Circuit Breaker, 100A, 100mA

  • RS-stocknr. 916-0397
  • Fabrikantnummer EUR1100.100/2
  • Fabrikant Europa
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: CN
Productomschrijving

Europacomponents EUR1 Series RCCB

Europa Components EUR1 RCCB series provide ground fault protection by monitoring the leakage of current to ground when used with standard MCBs. The EUR1 series are compact DIN Rail-mounted RCCBs and feature a wide range of trip ratings to offer complete protection for commercial or industrial applications.

Compact AC DIN Rail mount 2 and 4 Pole RCCB’s
Protects against the effects of sinusoidal alternating earth fault currents
Protects against indirect contact, with additional protection against direct contact
Command and isolation of resistive and inductive circuits
Suitable for residential and commercial applications

Note

RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with an MCB or a fuse to protect them against overcurrent and short circuits).

Europacomponents Circuit Protection Devices

Specificaties
Kenmerk Waarde
Current Rating 100A
Number of Poles 2
Trip Sensitivity 100mA
Tripping Characteristics Type AC
Mounting Style DIN Rail Mount
Application Residential
Overall Length 36mm
Terminal Contact Type Screw
Special Features Earth Fault Safety Protection
Circuit Breaker Type RCCB
Rated AC Voltage 230 → 400V
Reset Actuator Type Toggle Switch
Overall Depth 66mm
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 11-08-2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
91,12
(excl. BTW)
110,26
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 91,12
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
The ABB F200 series residual current circuit breaker ...
Description:
The ABB F200 series residual current circuit breaker is a 2-pole type B device. It has an electrical rating of 230V and 16A. The operation of the residual circuit breaker is indicated using a green LED. This circuit can operate ...
Type F RCDs offer the same range of ...
Description:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according ...