PNOZmulti 2 PNOZ m EF Input Module, 16 Inputs, 24 V dc

  • RS-stocknr. 918-6601
  • Fabrikantnummer 772140
  • Fabrikant Pilz
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

PNOZ m EF 16DI Safe Input Module

The PNOZ m EF 16DI expansion module connects to a base unit from the configurable control system.

Features and Benefits

Can be configured in the PNOZmulti Configurator
16 safe inputs
LED for error messages and diagnostics
Test pulse outputs used to monitor shorts across the inputs

Applications

The PNOZ m EF 16DI can connect E-stops, two-hand buttons, light beams, scanners, enabling switches, safety gate switches, PSEN and operating mode selector switches.

Standards

EN ISO 13849-1 PLe; EN ISO 13849-1 Cat. 4; EN 62061 SIL CL 3.

Approvals

CE, cULus Listed, TÜV, BG, CCC.

Supplied with

Screw terminals.

Specificaties
Kenmerk Waarde
Range PNOZmulti 2
Series PNOZ m EF
Type Input Module
For Use With PNOZmulti 2
Supply Voltage 24 V dc
Number of Inputs 16
Mounting Style DIN Rail
Dimensions 101.4 x 22.5 x 120 mm
Terminal Type Screw
9 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
16 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
242,00
(excl. BTW)
292,82
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 242,00
Related Products
The Preventa XPSMCM safe relay output modules have ...
Description:
The Preventa XPSMCM safe relay output modules have a compact designed, 22.5 x 99 x 114.5 mm, the same size as a typical safety relay. Removable screw-type terminal blocks for connecting the machine bus or networks channels and/or the power ...
Input expander / PFB. For parallel IO devicesPassive ...
Description:
Input expander / PFB. For parallel IO devicesPassive field box for series-wiringFor devices with M12 Connector, 8-poleFor up to 4 safety switchgearsFuse protected device portsHeavy duty version for field installationProtection class IP67.
Designed to be an expansion relay for use ...
Description:
Designed to be an expansion relay for use with the Minotaur safety relays. Typically used in safety system applications where additional output switching connections are needed to help shut down a manufacturing process, properly and safely.Can be connected as a ...
Fit for signal evaluation of outputs of safety ...
Description:
Fit for signal evaluation of outputs of safety magnetic switches2 safety contacts, Stop Category 06 Signalling outputsMulti-evaluation of up to 6 safety guardsSuitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks.