MTL 22 V ac, 32 V dc 20kA SD Surge Protection Device, DIN Rail Mounting

  • RS-stocknr. 251-3823
  • Fabrikant MTL
Datasheets
Wetgeving en compliance
N.v.t.
Productomschrijving

Ultra-Slim Loop Protector

Ultra-slim devices for protecting electronic equipment against surges on control loop cabling.

Full hybrid surge protection to BS6651 (category C)
Ultra-slim 7mm module, DIN-rail mounting and earthing
Protection for 4-20mA loops
Auto-reset

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Specificaties
Kenmerk Waarde
Suppressor Type Surge Protection Device
Maximum Voltage Rating 22 V ac, 32 V dc
Mounting Type DIN Rail
Maximum Surge Current 20kA
Series SD
Length 7mm
Depth 109.6mm
Height 99mm
Dimensions 7 x 109.6 x 99mm
Minimum Operating Temperature -40°C
Maximum Operating Temperature +80°C
58 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
130,34
(excl. BTW)
157,71
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 130,34
10 - 19
€ 117,57
20 - 24
€ 114,70
25 - 49
€ 108,96
50 +
€ 103,49
Related Products
Delta connected flexible wire ended universal DIN rail ...
Description:
Delta connected flexible wire ended universal DIN rail mounting RC contact arc suppressors designed to be connected across switching contacts of Control/Switchgear ContactorsIdeal for applications where inductive loads are switched and contact arc reduction is required to prolong contact life. ...
Frequency error range detection 35-75 HzOperating voltage 90V ...
Description:
Frequency error range detection 35-75 HzOperating voltage 90V to 300VLow voltage protection (LVD) Range 50V to 300VHigh voltage protection (HVD) Range 50V to 300V TimeSave™ function (Intelligent time delay)AVS™ function (Automatic Voltage Switcher) Programmable startup delay (0-1000hr range).
Valvetrab Surge protection for Photovoltaic equipment provides an ...
Description:
Valvetrab Surge protection for Photovoltaic equipment provides an effective method of limiting high-energy transients such as lightning strikes. These are a type 2 protective measure for green renewable energy PV systems which significantly increases their availability and operability. The Valvetrab ...
Type 1 and 2 prewired spark gap based ...
Description:
Type 1 and 2 prewired spark gap based combined lightning current and surge arresters consisting of a base and plug in modules. Maximum system availability and reliability due to the RADAX Flow follow current limitationNo tripping of 20amp gL/gG fuses ...