2 Output Toroidal Transformer, 30VA, 2 x 15V ac

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: IN
Productomschrijving

Toroid open wound 230V primary

High quality open style toroidal transformers with single 230Vac 50/60Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.

Small size and low weight compared with traditional stacked lamination types
Extremely low level of radiated magnetic field
Very low induced noise (hum)
Very low iron loss
Double insulated primary leads

Note

Mounting hardware is not supplied, available seperately

Approvals

UL506, EN61558

Toroidal 230Vac Primary 15VA to 1000VA

Warning

  • Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac
Secondary Voltage Rating 2 x 15V ac
Power Rating 30VA
Number of Outputs 2
Secondary Current 1A
Height 32mm
Weight 503g
Diameter 70mm
Dimensions 70 (Dia.) x 32mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Termination Type Copper Conductor Termination Wire
30 op voorraad - levertijd is 2 werkdag(en).
Prijs Each (In a Box of 30)
11,768
(excl. BTW)
14,239
(incl. BTW)
Aantal stuks
Per stuk
Per doos*
30 - 120
€ 11,768
€ 353,04
150 - 270
€ 10,337
€ 310,11
300 - 420
€ 10,065
€ 301,95
450 - 720
€ 9,807
€ 294,21
750 +
€ 9,562
€ 286,86
*prijsindicatie
Related Products
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA(503-928).
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. Single-phase single-winding safety and isolation transformers.Able to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting.
Single-phase control and signalling transformers (50 → 60 ...
Description:
Single-phase control and signalling transformers (50 → 60 Hz - class 1).Active parts protected by cover up to 1000 VA.Mounting on full or perforated platinum, or rail according to power.Direct mounting possible on symmetrical DIN rail up to 250 VA.More ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.