Phoenix Contact ELR H5-SC- 24DC/500AC-9 Motor Starter - 4 kW Rating, 24 V dc

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: DE
Productomschrijving

Phoenix Contact CONTACTRON '3 in 1' Hybrid Motor Starters

The Phoenix Contact ATEX approved, ELR series of Contactron 3 in 1 hybrid motor starters.The forward running motor starters are designed for DIN Rail mounting and for starting 3 phase motors up to 500 V ac where adjustable overload shutdown and emergency stop function is to safety integrity level 3 (SIL 3) and performance level E (PL e).

Features and Benefits

• ATEX approved
• IP20 protection
• Screw connection
• Adjustable overload shutdown
• Emergency stop to SIL 3/PL e
• Needs little space (only 22.5 mm wide)
• Less wiring time and expense (up to 75% less wiring time compared to conventional contactors)
• Easy DIN rail mounting
• Low-wear switching
• Adjustable current for bimetal function
Standards
IEC 60947-1, IEC 60947-4-2, IEC 61508, ISO 13849, ATEX

Specificaties
Kenmerk Waarde
Series ELR H5-SC- 24DC/500AC-9
Component Type Hybrid Motor Starter
Range Contactron
Power Rating 4 kW
Control Voltage 24 V dc
Size 22.5 x 106.6 x 113.7mm
Mounting Type DIN Rail
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 04-11-2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
90,45
(excl. BTW)
109,44
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
€ 90,45
5 - 9
€ 87,90
10 +
€ 86,84
Related Products
Sirius 3RM1 motor starters are compact 22.5 mm ...
Description:
Sirius 3RM1 motor starters are compact 22.5 mm wide devices that combine various functions in a single enclosure.They consist of combinations of relay contacts, power semiconductors (hybrid technology), and an electronic overload relay for switching induction under normal operating conditions. ...
Ideal to satisfy the basic protection requirements for ...
Description:
Ideal to satisfy the basic protection requirements for motor starters; thermal overload and short-circuit. Protection against overloads and short-circuitsProtection against phase failure and phase imbalanceProtection against insulation breaks (equipment protection only)Manual resetClass 10 for 3-phase motors.
Single-phase failure via thermal electromagnetic trips are featured ...
Description:
Single-phase failure via thermal electromagnetic trips are featured in these circuit breakers/manual motor starters. The respective switch position is clearly indicated by the switch handle. Terminals are protected against accidental contact. They have a terminal cross section of up to ...
These motor starters are available in a selection ...
Description:
These motor starters are available in a selection of formats. All have removable steel base plates for rigidity when mounting to an uneven surface and ease of earthing and wiring and an impact resistant polycarbonate front cover which is adaptable ...