Keysight Technologies U1194A Clamp Meter, Max Current 600A ac, 600A dc CAT III 600 V, CAT IV 300 V

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: TW
Productomschrijving

Keysight U1194A Clampmeter True-rms

Keysight U1190 Series clampmeters are built to perform in the environments that users work in. Current measurement is up to an impressive 600A. These instruments are ergonomically designed to fit comfortably in the palm of the hand and allow selection of measurement functions with a simple thumb press.

Unique wire separator to separate wires from a bundle
Vsense to perform non-contact voltage detection
Built-in LED flashlight to illuminate test area
Visual (backlight alert) and audible continuity indication in noisy environments
Current measurement up to 600A
Digital multimeter (DMM) with resistance, capacitance, DCV, ACV, DCA, ACA, DCμA and ACμA measurement capabilities
Continuity and diode test measurements
Operating temperature from -10 to 50 °C, 0 to 80% RH
Temperature: K-type: -40 to 1,200 °C
CAT III 600V / CAT IV 300V safety rating
Battery type 2 x 1.5 V AAA Alkaline battery
Display Liquid crystal display (LCD)
Auto power OFF

Supplied with

Quick Start Guide, Certificate of calibration, Test leads with 4-mm tips, K-type thermocouple, 1.5 V AAA Alkaline battery, Soft carrying case

Specificaties
Kenmerk Waarde
Absolute Maximum AC Current Measurement 600A ac
Absolute Maximum DC Current Measurement 600A dc
Absolute Maximum AC Voltage Measurement 600V ac
Absolute Maximum DC Voltage Measurement 600V dc
Absolute Maximum Resistance Measurement 60kΩ
Model Number U1194A
AC Current Measurement Resolution 10nA
DC Current Measurement Resolution 10nA
Best DC Current Accuracy ±(1% rdg + 5dgts)
Clamp Meter Type Multifunction Clamp
Best AC Current Accuracy ±(1% rdg + 5dgts)
Best AC Voltage Accuracy ±(1.2% rdg + 5dgts)
Best DC Voltage Accuracy ±(0.5% rdg + 3dgts)
Non-Contact Voltage Detector Yes
True RMS Yes
Power Source Battery
Display Type LCD
Battery Type AAA
Best Temperature Measurement Accuracy ±1% + 2 °C
Width 77.1mm
Minimum Operating Temperature -10°C
Jaw Capacity Busbars 35mm
Resistance Measurement Resolution 100mΩ
Dimensions 225 x 77.1 x 38.6mm
Safety Category Level CAT IV, CAT lll
Maximum Operating Temperature +50°C
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature
Best Resistance Measurement Accuracy ±0.8% + 3 Digits
Height 38.6mm
DC Voltage Measurement Resolution 10mV
Battery Life 40 (Backlight On) h, 200 (Backlight Off) h
Absolute Maximum Temperature Measurement +1200°C
Maximum Conductor Size 35mm
Length 225mm
Safety Category Voltage 300 V, 600 V
Temperature Measurement Resolution 0.1°C
AC Voltage Measurement Resolution 10mV
Weight 348g
Safety Category CAT III 600 V, CAT IV 300 V
12 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
257,00
(excl. BTW)
310,97
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 257,00
Kalibratie-opties
Related Products
Featuring current clamp, multimeter and thermometer functions, RS ...
Description:
Featuring current clamp, multimeter and thermometer functions, RS Pro ICM134 is ideally suited to HVAC and electrical maintenance applications up to 600 A ac. 4000 Count large backlit LCD display750 V ac / 1000 dc voltage measurement600 A ac current ...
Digital AC and DC clamp meter with True-RMS ...
Description:
Digital AC and DC clamp meter with True-RMS reading, Dual hall sensor and a Nickel-Steel alloy jaw mechanism. True-RMS reading4000 Count digital displayAuto-rangingDual hall sensorNickel-Steel alloy jaw mechanismAC-DC 300 AAC-DC 600 V0.5% basic DC Voltage accuracy1.5% basic AC Voltage accuracy1.0% ...
The FLIR CM174 and CM275 clamp meters bring ...
Description:
The FLIR CM174 and CM275 clamp meters bring the power Infrared Guided Measurement (IGM) together with a range of electrical measurement features, so you can visually identify electrical problems and solve complex issues quickly. The CM275 also helps streamline inspections ...
Standard: IEC 1010-1 Cat. III, deg. 2. Hall ...
Description:
Standard: IEC 1010-1 Cat. III, deg. 2. Hall effect current probes allowing measurement of direct or alternating currents, without disturbing or breaking the circuit.Multimeter output (PAC 10 and 11).Voltage output.Zero adjustment using a thumb wheel (PAC 10) or automatically by ...