CHB5 Leakage Current Clampmeter
Digital Leakage Current Clamp meter (German version) with Harmonic measurement TRMS (AC) functions
4 digit liquid-crystal display
Manual range selection for current and voltage measurements
Current Measurements
Leakage Current Measurement
Voltage Measurement
Harmonics of AC Current in Magnitude (mA or A) or in Percentage (%)
Total Harmonic Distortion (% THD-F)
Harmonic measurement (up to 99th harmonic)
Crest Factor (C.F.)
True RMS Measurement
MIN/MAX/Peak Measurement
Contactless frequency measurement
Hold function
0.01 mA resolution
30 mm diameter conductor jaw capacity
Auto power-off
Safety to DIN VDE 0411/EN 61010 / IEC 61010
Manual range selection for current and voltage measurements
Current Measurements
Leakage Current Measurement
Voltage Measurement
Harmonics of AC Current in Magnitude (mA or A) or in Percentage (%)
Total Harmonic Distortion (% THD-F)
Harmonic measurement (up to 99th harmonic)
Crest Factor (C.F.)
True RMS Measurement
MIN/MAX/Peak Measurement
Contactless frequency measurement
Hold function
0.01 mA resolution
30 mm diameter conductor jaw capacity
Auto power-off
Safety to DIN VDE 0411/EN 61010 / IEC 61010
Standards
CAT II/600 V, CAT III/300 V
Supplied with
2 x test leads with probes (red/black), 2 x 1,5V IEC LR6 batteries, holster, instruction manual
Buy a Fluke, Get one Free is back!!
Between March 1st, 2024 and August 31st, 2024, the customer spends €150 or more on a qualifying Fluke product (Fluke Industrial, Fluke Calibration, Fluke Networks, or Beha-Amprobe).
Customer claims their tool online at: www.fluke.com/en/freefluke
A proof of purchase in the form of a receipt or invoice is required.
Note: Offer not available in South Africa
Between March 1st, 2024 and August 31st, 2024, the customer spends €150 or more on a qualifying Fluke product (Fluke Industrial, Fluke Calibration, Fluke Networks, or Beha-Amprobe).
Customer claims their tool online at: www.fluke.com/en/freefluke
A proof of purchase in the form of a receipt or invoice is required.
Note: Offer not available in South Africa
Kenmerk | Waarde |
---|---|
Absolute Maximum AC Current Measurement | 50A ac |
Absolute Maximum AC Voltage Measurement | 600V ac |
Model Number | CHB5 |
Calibrated | RSCAL |
AC Current Measurement Resolution | 10µA ac |
Clamp Meter Type | Leakage Clamp Meter |
Best AC Current Accuracy | ±1.5% + 5 Digits |
Best AC Voltage Accuracy | ±1.5% + 5 Digits |
Functions Measured | AC Current, AC Voltage |
True RMS | Yes |
Jaw Capacity Busbars | 30mm |
Display Type | LCD |
Maximum Operating Temperature | +50°C |
Minimum Operating Temperature | -10°C |
Height | 35.6mm |
AC Voltage Measurement Resolution | 0.1V ac |
Maximum Conductor Size | 30mm |
Weight | 200g |
Safety Category Level | CAT II, CAT III |
Safety Category Voltage | 300 V, 600V |
Battery Type | LR6 |
Power Source | Battery |
Width | 62mm |
Length | 210mm |
Dimensions | 210 x 62 x 35.6mm |
Safety Category | CAT II 600 V, CAT III 300V |
- RS-stocknr.:
- 912-0043
- Fabrikantnummer:
- CHB5
- Fabrikant:
- Beha-Amprobe
N.v.t.
- Land van herkomst:
- TW
CHB5 Leakage Current Clampmeter
Digital Leakage Current Clamp meter (German version) with Harmonic measurement TRMS (AC) functions
4 digit liquid-crystal display
Manual range selection for current and voltage measurements
Current Measurements
Leakage Current Measurement
Voltage Measurement
Harmonics of AC Current in Magnitude (mA or A) or in Percentage (%)
Total Harmonic Distortion (% THD-F)
Harmonic measurement (up to 99th harmonic)
Crest Factor (C.F.)
True RMS Measurement
MIN/MAX/Peak Measurement
Contactless frequency measurement
Hold function
0.01 mA resolution
30 mm diameter conductor jaw capacity
Auto power-off
Safety to DIN VDE 0411/EN 61010 / IEC 61010
Manual range selection for current and voltage measurements
Current Measurements
Leakage Current Measurement
Voltage Measurement
Harmonics of AC Current in Magnitude (mA or A) or in Percentage (%)
Total Harmonic Distortion (% THD-F)
Harmonic measurement (up to 99th harmonic)
Crest Factor (C.F.)
True RMS Measurement
MIN/MAX/Peak Measurement
Contactless frequency measurement
Hold function
0.01 mA resolution
30 mm diameter conductor jaw capacity
Auto power-off
Safety to DIN VDE 0411/EN 61010 / IEC 61010
Standards
CAT II/600 V, CAT III/300 V
Supplied with
2 x test leads with probes (red/black), 2 x 1,5V IEC LR6 batteries, holster, instruction manual
Buy a Fluke, Get one Free is back!!
Between March 1st, 2024 and August 31st, 2024, the customer spends €150 or more on a qualifying Fluke product (Fluke Industrial, Fluke Calibration, Fluke Networks, or Beha-Amprobe).
Customer claims their tool online at: www.fluke.com/en/freefluke
A proof of purchase in the form of a receipt or invoice is required.
Note: Offer not available in South Africa
Between March 1st, 2024 and August 31st, 2024, the customer spends €150 or more on a qualifying Fluke product (Fluke Industrial, Fluke Calibration, Fluke Networks, or Beha-Amprobe).
Customer claims their tool online at: www.fluke.com/en/freefluke
A proof of purchase in the form of a receipt or invoice is required.
Note: Offer not available in South Africa
Kenmerk | Waarde |
---|---|
Absolute Maximum AC Current Measurement | 50A ac |
Absolute Maximum AC Voltage Measurement | 600V ac |
Model Number | CHB5 |
Calibrated | RSCAL |
AC Current Measurement Resolution | 10µA ac |
Clamp Meter Type | Leakage Clamp Meter |
Best AC Current Accuracy | ±1.5% + 5 Digits |
Best AC Voltage Accuracy | ±1.5% + 5 Digits |
Functions Measured | AC Current, AC Voltage |
True RMS | Yes |
Jaw Capacity Busbars | 30mm |
Display Type | LCD |
Maximum Operating Temperature | +50°C |
Minimum Operating Temperature | -10°C |
Height | 35.6mm |
AC Voltage Measurement Resolution | 0.1V ac |
Maximum Conductor Size | 30mm |
Weight | 200g |
Safety Category Level | CAT II, CAT III |
Safety Category Voltage | 300 V, 600V |
Battery Type | LR6 |
Power Source | Battery |
Width | 62mm |
Length | 210mm |
Dimensions | 210 x 62 x 35.6mm |
Safety Category | CAT II 600 V, CAT III 300V |