Honeywell CSL Series Current Transformer, 9A Input, 9:1, -200 → +200 mA Output, 4.5 → 10.5 V dc
- RS-stocknr.:
- 121-8174
- Fabrikantnummer:
- CSLW6B200M
- Fabrikant:
- Honeywell
Momenteel niet beschikbaar
We weten niet of dit artikel weer voorradig zal zijn, het wordt door de fabrikant stopgezet.
- RS-stocknr.:
- 121-8174
- Fabrikantnummer:
- CSLW6B200M
- Fabrikant:
- Honeywell
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Honeywell | |
| Current Ratio | 9:1 | |
| Series | CSL | |
| Supply Voltage | 4.5 → 10.5 V dc | |
| Input Current | 9A | |
| Output Current | -200 → +200 mA | |
| Overall Height | 10mm | |
| Overall Width | 16.2mm | |
| Minimum Temperature | -25°C | |
| Maximum Temperature | +100°C | |
| Mounting Type | PCB Mount | |
| Alles selecteren | ||
|---|---|---|
Merk Honeywell | ||
Current Ratio 9:1 | ||
Series CSL | ||
Supply Voltage 4.5 → 10.5 V dc | ||
Input Current 9A | ||
Output Current -200 → +200 mA | ||
Overall Height 10mm | ||
Overall Width 16.2mm | ||
Minimum Temperature -25°C | ||
Maximum Temperature +100°C | ||
Mounting Type PCB Mount | ||
- Land van herkomst:
- NZ
Honeywell CSLW Series Hall Effect AC Current Sensor
CSLW Series miniature, open-loop AC current sensors from Honeywell. These sensors have a ratiometric output and incorporate a miniature linear Hall-effect sensor which is encapsulated in a PCB-mountable plastic package. A complete sensor is comprised of a sensor IC, flux collector, housing, and wound wire coil. The compact size is ideal for applications where space is limited.
Accurate, low-cost AC current sensing
Wired open-loop design with multiple turns for increased sensitivity
Linear ratiometric output
Current sinking or sourcing output
Low insertion loss with fast response time
Built-in temperature compensation for higher accuracy
Operating temperature range -25 to 100 °C
RoHs compliant (lead-free)
Wired open-loop design with multiple turns for increased sensitivity
Linear ratiometric output
Current sinking or sourcing output
Low insertion loss with fast response time
Built-in temperature compensation for higher accuracy
Operating temperature range -25 to 100 °C
RoHs compliant (lead-free)
Gerelateerde Links
- Honeywell CSL Series Current Transformer 57:1 8 → 16 V dc
- Honeywell Ratiometric Hall Effect Sensor switching current 1.5 mA supply voltage 4.5 → 10.5 V dc
- Honeywell Hall Effect Sensor 4.5 → 10.5 V dc
- Honeywell Through Hole Hall Effect Sensor 4.5 → 10.5 V dc
- Honeywell CSN Series Current Transformer 200:1 12 → 15 V dc
- Honeywell Current Transformers
- Honeywell Through Hole Hall Effect Sensor 4.5 → 10.5 V dc, 10.5V
- Honeywell Surface Mount Hall Effect Sensor 4.5 → 10.5 V dc, Block Body