Fluke 51 Digital Thermometer, 1 Input Handheld, E, J, K, T Type Input

  • RS-stocknr. 353-4449
  • Fabrikantnummer FLUKE-51-2
  • Warranty 3 jaar
  • Fabrikant Fluke
Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: CN
Productomschrijving

Fluke 50 Series II Thermometer

The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged, handheld test tool.

Fluke 51 II and 52 II Features

Model 51 II single input, Model 52 II dual input
Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX or AVG
Relative time clock on MIN, MAX and AVG provides a time reference for major events
Electronic offset function allows compensation of thermocouple errors to maximise overall accuracy
Measures J, K, T and E type thermocouples
Readout in °C, °F or Kelvin (K)
User-friendly front panel is easy to set up and operate
Sleep mode increases battery life

Fluke 53 II B and 54 II B Extra Features

Model 51-II single input: Model 52-II dual input
. Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX or AVG
. Relative time clock on MIN, MAX and AVG provides a time reference for major events
. Electronic offset function allows compensation of thermocouple errors to maximise overall accuracy
. Measures J, K, T and E type thermocouples
. Readout in °C, °F or Kelvin (K)
. User friendly front panel is easy to set up and operate
. Sleep mode increases battery life
. Battery door allows easy battery replacement without breaking the calibration seal
. Splash and dust resistant case protected by impact absorbing holster

Model 53 II B single input, Model 54 II B dual input
Data logging up to 500 points of data with user-adjustable recording interval
Extra thermocouple types N, R, S
Real-time clock captures the exact time of day when events occur
Recall function allows logged data to be easily reviewed on the meter display
Contents of thermometer memory can be transferred to PC using FlukeView Forms, available separately
Fluke 53-2B & 54-2B Compatible with the Fluke FVF- SC2 FlukeView software and USB lead RS 385-0599
IR communication port allows data to be exported to optional FlukeView™ Temperature PC software for further analysis and graphing

Fluke 53-2-B and 54-2B additional features:

Model 53-2-B single input: Model 54-2-B dual input
. Data logging up to 500 points of data with user adjustable recording interval
. Additional thermocouple types N, R, and S
. Real time clock captures the exact time of day when events occur
. Recall function allows logged data to be easily reviewed on the meter display
. You can transfer the contents of the thermometer’s memory to a PC using FlukeView Forms
. Fluke 53-2B & 54-2B Compatible with the Fluke FVF- SC2 FlukeView software and USB lead RS 385-0599
. IR communication port allows data to be exported to optional FlukeView™ Temperature PC software for further analysis and graphing

Note

Fluke 53-2B & 54-2B need the Fluke FVF- SC2 FlukeView software and USB lead RS 385-0599

Supplied with

Instruction leaflet, holster, battery (fitted)
1 off type K thermocouple (Model 51-II & model 53-2-B)
2 off type K thermocouple (Model 52-II & Model 54-2-B)

Specificaties
Kenmerk Waarde
Absolute Maximum Temperature Measurement +1372°C
Thermometer Type Handheld
Probe Type E, J, K, T
Application Industrial
Best Accuracy ±0.05 %
Number of Temperature Inputs 1
Resolution 0.1 °C
Length 173mm
Width 86mm
Height 38mm
Dimensions 173 x 86 x 38mm
Minimum/Maximum Recordings Yes
Weight 400g
Temperature Scale Centigrade, Fahrenheit
Model Number p RS51
Battery Type AA
3 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
45 op voorraad - levertijd is 2 werkdag(en) (UK-voorraad)
Prijs Each
337,00
(excl. BTW)
407,77
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 337,00
Related Products
This intrinsically safe thermometer is approved for use ...
Description:
This intrinsically safe thermometer is approved for use in potentially explosive atmospheres (group IIC gas types and T4) in Zone 1 hazardous areas. Basic temperature monitoring features including K type thermocouple selection and the choice of two resolution scalingsDesigned for ...
BacklightDisplay holdOptional auto power off after 12 minutesLow ...
Description:
BacklightDisplay holdOptional auto power off after 12 minutesLow battery indicationSet up retention (when switched on the last settings used are displayed)K-type thermocouple based industrial thermometersDesigned to suit a wide variety of process, industrial and HVAC applicationsDual input°C/°F ...
BacklightDisplay holdOptional auto power off after 12 minutesLow ...
Description:
BacklightDisplay holdOptional auto power off after 12 minutesLow battery indicationSet up retention (when switched on the last settings used are displayed)Pt-100 based, high accuracy thermometerDesigned to suit a wide variety of process and industrial applications including calibration checking°C/°F selectionRange ...
LCD compact digital/virtual analogue indicators with common dimensions ...
Description:
LCD compact digital/virtual analogue indicators with common dimensions requiring a single 5.5mm diameter mounting hole unless specified otherwise. A rubber seal is included providing splash proof protection for the units when fitted to the meter during installation. All have an ...