BK Precision 891 Bench LCR Meter 100 mF, 100 mΩ, 9999 h

Subtotaal (1 eenheid)*

€ 1.864,30

(excl. BTW)

€ 2.255,80

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 6 stuk(s) vanaf 13 april 2026
  • Plus verzending 17 stuk(s) vanaf 13 april 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 1.864,30

*prijsindicatie

RS-stocknr.:
121-7581
Artikelnummer Distrelec:
301-15-347
Fabrikantnummer:
BK891
Fabrikant:
BK Precision
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

BK Precision

Maximum Capacitance Measurement

100mF

Product Type

LCR Meter

Maximum Resistance Measurement

100mΩ

Accuracy

±0.05 %

Maximum Inductance Measurement

9999h

Maximum Test Frequency

300kHz

Display Type

LCD

Power Source

Mains

Weight

3.4kg

Height

381mm

LCR Type

Bench

Length

258mm

Standards/Approvals

No

Maximum Operating Temperature

40°C

Minimum Operating Temperature

0°C

Plug Type

Type C, 3-Pin (Global)

Model Number

891

Width

113 mm

Niet conform

Land van herkomst:
TW

B&K Precision Model 891 Bench LCR Meter


B&K Precision model BK891 is capable of measuring inductors, capacitors and resistors at DC or from 20 Hz to 300 kHz. The instrument's compact 2U half-rack form factor is suitable for the bench or rack mount installation. A large 4.3 in colour display, with all important parameters and measurements visible on one screen, makes this meter easy-to-operate.

The instrument's convenient bin sorting function and frequency sweep function enable quick sorting and characterisation of components. Standard USB, GPIB and LAN interfaces enhance productivity by providing remote control capabilities to perform daily operations in production, quality control and laboratory environments. Also includes user manual, power cord, Kelvin clips (TL 889A), certificate of calibration and test report.

Features and Benefits:


• Measurement parameters L, C, R, Z, G, B, Y, D, Q, θ, DCR

• 0.05% best impedance accuracy

• Fully adjustable test frequency from 20 Hz to 300 kHz with 4-digit resolution

• 0.5 Vrms and 1 Vrms selectable test levels

• Adjustable measurement speed for fast readout or better accuracy

• 300-point linear and logarithmic sweep function

• Bin sorting function (9 primary, one secondary and one out-of-spec bin)

• Save/recall up to 100 setups (10 internal) including 1000 measurements and screenshots

Supplied with

User manual, power cord, Kelvin clips (TL 889A), certificate of calibration & test report