Productomschrijving
Level Sensing Relay
Dual voltage sensing relay 115/230V AC
Single or two point level control
Selectable 'Pump-up' or 'Pump-down' modes
Variable sensitivity; 2kΩ on, 5kΩ off, to 20kΩ on, 50kΩ off
LED indication of relay and supply status
Panel cutout (mm): 45 x 45
Single point level; relay energises (Pump-up) / de-energises (Pump-down) when liquid level drops below the set level electrode
Two point level; relay energises when liquid level drops below low level electrode and de-energises when level reaches high level electrode (Pump-up)
Relay de-energises when liquid level drops below low level electrode and energises when level reaches high level electrode (Pump-down)
Single or two point level control
Selectable 'Pump-up' or 'Pump-down' modes
Variable sensitivity; 2kΩ on, 5kΩ off, to 20kΩ on, 50kΩ off
LED indication of relay and supply status
Panel cutout (mm): 45 x 45
Single point level; relay energises (Pump-up) / de-energises (Pump-down) when liquid level drops below the set level electrode
Two point level; relay energises when liquid level drops below low level electrode and de-energises when level reaches high level electrode (Pump-up)
Relay de-energises when liquid level drops below low level electrode and energises when level reaches high level electrode (Pump-down)
Liquid Level Relays are used to monitor the levels of conductive liquids, and are available in Up/Down, Minimum, Maximum, and Fill/Empty variations. Liquid Level Relays are straightforward to install and safe to use.
Application Examples
Liquid Level Relays (Conductive Level Sensors) are used in a wide variety of applications including waste water management and the monitoring and management of corrosive liquid media, and designed specifically to provide for the:
Monitoring and control of liquid levels
Protection of pumps against dry running
Ability to detect liquid leaks in a system
Control of media mixing ratios
Control of liquid levels
Protection of pumps against dry running
Ability to detect liquid leaks in a system
Control of media mixing ratios
Control of liquid levels
Specificaties
Kenmerk | Waarde |
---|---|
Number of Inputs | 2 |
Mounting Style | Panel Mount |
Probe Voltage | 17V ac |
Supply Voltage | 115 V ac, 230 V ac |
Overall Length | 75mm |
Overall Width | 48mm |
Overall Depth | 48mm |
Minimum Operating Temperature | -20°C |
Maximum Operating Temperature | +60°C |