Eaton xEffect FAZ MCB Mini Circuit Breaker 1P, 2 A, 10 kA, Curve C

  • RS-stocknr. 922-6999
  • Fabrikantnummer FAZ-C2/1
  • Fabrikant Eaton
Datasheets
Wetgeving en compliance
Conform
Land van herkomst: ES
Productomschrijving

Eaton FAZ Series MCBs

Eaton FAZ- miniature circuit breakers are Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit, Trip-free design. Breaker cannot be defeated by holding the handle in the ON position

Features and Benefits

Thermal-magnetic overcurrent protection
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm

Standards

IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).

Q: What is the differences in the Tripping Curves B, C, D and S?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Curve S Tripping 13 to 17 times the rated current
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies

Standards

IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2

Specificaties
Kenmerk Waarde
Range XEffect
Series FAZ
Number of Poles 1
Current Rating 2 A
Tripping Characteristics Type C
Rated AC Voltage 240 V
Rated DC Voltage 48V
Breaking Capacity 10 kA
Length 17.8mm
Width 65.5mm
Depth 80mm
Reset Actuator Type Toggle Switch
Special Features Current Limiting Design Provides Fast Short-Circuit Interruption, Designed for Inductive Loads, Field-Installable Shunt Trip and Auxiliary Switch Subsequent Mounting, Possibility for Sealing the Toggle In ON or OFF Position, Suitable For Branch Circuit Device Protection, Thermal-Magnetic Overcurrent Protection
Circuit Breaker Type MCB
Break Time Instantaneous
Terminal Contact Type Screw
Tripping Mechanism Thermal-Magnetic
Application Appliances, Business Equipment, Control Circuit, Lighting, Supplementary Protection
Tijdelijk niet op voorraad – nieuwe voorraad verwacht op 28-08-2020, met een levertijd van 1 werkdag.
Prijs Each
23,68
(excl. BTW)
28,65
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 23,68
Related Products
Professional range of Eaton Memshield miniature circuit breakers. ...
Description:
Professional range of Eaton Memshield miniature circuit breakers. The MCBs are designed to deliver safe, reliable and high performance protection on electrical power distribution systems. Complies with BS EN 60898Accept cable up to 25mm²Thermal/magnetic operationPositive contact indication (red-on, green-off)1 or ...
Type K characteristics have been specifically designed for ...
Description:
Type K characteristics have been specifically designed for the protection of motor control circuits and items used within them. It has a very sensitive thermal curve, combined with a magnetic setting of 8 times the normal input current (In), which ...
The ABB S200 Series of MCB offer a ...
Description:
The ABB S200 Series of MCB offer a compact solution for protection requirements. These miniature circuit breakers are current limiting; DIN rail mounted and can offer a good equivalent to fused systems.Type K characteristics have been specifically designed for the ...
Thermal-magnetic circuit breakers with positive contact indication for ...
Description:
Thermal-magnetic circuit breakers with positive contact indication for control, protection against short-circuits and overloads, and isolation of electrical circuits. C curveConnections: auto / screw or screw / screw.