Phoenix Contact PSR-CT-C-SEN-1-8 Series RFID Non-Contact Safety Switch, 24V dc, Polybutylene Terephthalate Housing, M12
- RS-stocknr.:
- 190-8415
- Fabrikantnummer:
- 2702972
- Fabrikant:
- Phoenix Contact
Bekijk deze categorie
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 14-06-2023, met een levertijd van 2 à 3 werkdagen.
Prijs Each
€ 140,77
(excl. BTW)
€ 170,33
(incl. BTW)
Aantal stuks | Per stuk |
1 + | € 140,77 |
- RS-stocknr.:
- 190-8415
- Fabrikantnummer:
- 2702972
- Fabrikant:
- Phoenix Contact
- Land van herkomst:
- DE
Datasheets
Wetgeving en compliance
- Land van herkomst:
- DE
Productomschrijving
Proximity safety circuit, unicode sensor with RFID coding, model 4, automatic or manual start, integrated diagnostics, 24 V DC supply, M12 connector.
The PSR-CT safety circuit consists of a combination of a PSR-CT-...-SEN-1-8 sensor with varying coding types and a coded PSR-CT-C-ACT actuator. It provides maximum tamper protection and the highest level of safety. The PSR-CT safety circuit is available with the following types of coding:
Fixcode: For the sensor to detect the actuator, the actuator must first be associated with the sensor via a learning process. The learning process can only be completed once. The sensor and actuator are then permanently assigned to each other by their coding. Safety circuits with fixcode evaluation achieve a high coding level.
Unicode: For the sensor to detect the actuator, the actuator must first be assigned to the sensor via a learning process. The learning process for a new actuator can be repeated any number of times. The sensor only detects the last learned actuator. Safety circuits with unicode evaluation achieve a high coding level.
Multicode: The sensor detects every actuator of the approved type. No specific actuator code can be assigned. Safety circuits with multicode evaluation achieve a low coding level.
The PSR-CT safety circuit consists of a combination of a PSR-CT-...-SEN-1-8 sensor with varying coding types and a coded PSR-CT-C-ACT actuator. It provides maximum tamper protection and the highest level of safety. The PSR-CT safety circuit is available with the following types of coding:
Fixcode: For the sensor to detect the actuator, the actuator must first be associated with the sensor via a learning process. The learning process can only be completed once. The sensor and actuator are then permanently assigned to each other by their coding. Safety circuits with fixcode evaluation achieve a high coding level.
Unicode: For the sensor to detect the actuator, the actuator must first be assigned to the sensor via a learning process. The learning process for a new actuator can be repeated any number of times. The sensor only detects the last learned actuator. Safety circuits with unicode evaluation achieve a high coding level.
Multicode: The sensor detects every actuator of the approved type. No specific actuator code can be assigned. Safety circuits with multicode evaluation achieve a low coding level.
Specificaties
Kenmerk | Waarde |
Supply Voltage | 24V dc |
Housing Material | Polybutylene Terephthalate (PBT) |
Connection Type | M12 |
Actuator Type | Magnetic |
Sensor Principle | RFID |
Switching Distance | 140 (Between Two Safety Circuits) mm, 7 (Between Sensor and Actuator when Traveling in the Y-Direction) mm |
Series | PSR-CT-C-SEN-1-8 |
IP Rating | IP65, IP67, IP69, IP69K |
Supply Current | 40mA |
Length | 26.5mm |
Depth | 40mm |
Safety Category | 4 |
Width | 18mm |