12V ac 2 Output Through Hole PCB Transformer, 6VA

Datasheets
Wetgeving en compliance
Conform
Land van herkomst: PL
Productomschrijving

PCB Mount 115/230Vac Transformer

Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation
Fully shrouded bobbins
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

//media.rs-online.com/t_line/L231852-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 12V ac
Power Rating 6VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 43mm
Width 36mm
Depth 33mm
Dimensions 43 x 36 x 33mm
Weight 180g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
61 op voorraad - levertijd is 2 werkdag(en).
Prijs Each
10,58
(excl. BTW)
12,80
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 10,58
10 - 24
€ 9,83
25 - 49
€ 9,40
50 +
€ 8,65
Related Products
Fully shrouded bobbins Extra pins for secure board ...
Description:
Fully shrouded bobbins Extra pins for secure board mounting 100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).