PCB Mount 115/230Vac Transformer

Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation
Fully shrouded bobbins
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation (Primary to Secondary) 4 kV rms
Isolation (Windings to core) 2 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
//media.rs-online.com/t_line/L231852-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin construction
Full varnish impregnation

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 12V ac
Power Rating 6VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 43mm
Width 36mm
Depth 33mm
Dimensions 43 x 36 x 33mm
Weight 180g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
184 op voorraad - levertijd is 2 werkdag(en).
Prijs Each
10,58
(excl. BTW)
12,80
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 10,58
10 - 24
€ 9,83
25 - 49
€ 9,40
50 +
€ 8,65
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary windingThese transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and ...
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings ...
Description:
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedHigh efficiency and ...