Fluke 62 MAX+ Infrared Thermometer, -30 °C Min, 650 °C Max, ±1 % Accuracy, °C, Fahrenheit, F Measurements

Subtotaal (1 eenheid)*

€ 168,00

(excl. BTW)

€ 203,28

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks
Per stuk
1 +€ 168,00

*prijsindicatie

Kalibratie-opties

Per stuk

€ 302,00

(excl. BTW)

€ 365,42

(incl. BTW)

RS-stocknr.:
760-0389
Fabrikantnummer:
FLUKE-62 MAX +
Fabrikant:
Fluke
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Fluke

Maximum Temperature Measurement

650°C

Product Type

Infrared Thermometer

Battery Type

AA

Temperature Scale

°C, Fahrenheit, F

Accuracy

±1 %

Distance to Spot Ratio

12:1

Minimum Temperature Measurement

-30°C

Emissivity

0.1 to 1, Adjustable

Model Number

62 MAX+

Resolution

0.1 °C

Response Time

300ms

Battery Life

8h

Width

85mm

Weight

255g

Hazardous Area Certification

NO

Standards/Approvals

IEC 61010-1

Length

175mm

Height

75mm

Vrijgesteld

Fluke Infrared Thermometer, ±1°C Accuracy, -30°C Minimum Temperature Measurement - FLUKE-62 MAX+


This infrared thermometer is a Compact handheld instrument designed to measure surface temperatures quickly and safely in industrial settings. It provides non-contact readings across a wide temperature range and is intended for use in automation, electronics, electrical and mechanical environments where Rapid diagnostics and remote measurement reduce downtime and exposure risks.

Features & Benefits


• 12:1 D:S optics deliver accurate targeting at distance
• Measurement range -30 to 650°C for broad application coverage
• Adjustable emissivity IR thermometer for varied surface types
• Fluke 62 MAX+ accuracy ±1°C for precise readings
• High-resolution 0.1°C infrared thermometer improves detectability
• Fast response 500 MS temperature gun speeds troubleshooting

**Applications**


• Suitable for inspecting motor bearings and drive components
• Ideal for checking PCB hotspots on electronic assemblies
• Used for verifying HVAC duct and vent temperatures
• Can be used for preventive checks on electrical switchgear
• Suitable for thermal spot checks in fabrication and maintenance

What power source does it use and how long does it operate on a single cell?


It is battery powered using a single AA cell and provides around 8 hours of operation with the laser and backlight on.

How is the measurement spot defined for precise readings?


The device uses dual rotating lasers to indicate the measurement area, where the actual spot corresponds to the space between the two dots.

What environmental protection and durability features support field use?


The instrument meets IP54 for dust and splash resistance and withstands a 3M drop test for rugged handling.

What safety and industry standard applies to its electrical design?


It is produced in line with IEC 61010-1 requirements for measurement equipment safety.

Approvals

FDA and EN 60825-1 Class II

Standards

EN/IEC 61010-1: 2001