Fluke 374 FC Clamp Meter, 600 A dc 600 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS-stocknr.:
- 905-5911
- Artikelnummer Distrelec:
- 300-37-361
- Fabrikantnummer:
- FLUKE-374 FC
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 615,00
(excl. BTW)
€ 744,15
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 72 stuk(s) klaar voor verzending
- 44 stuk(s) klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 615,00 |
*prijsindicatie
- RS-stocknr.:
- 905-5911
- Artikelnummer Distrelec:
- 300-37-361
- Fabrikantnummer:
- FLUKE-374 FC
- Fabrikant:
- Fluke
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 100mΩ | |
| Maximum DC Current Measurement | 600A dc | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 6kΩ | |
| Model Number | 374 FC | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| AC Current Resolution | 100mA | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Resolution | 100mV ac | |
| Maximum Jaw Opening | 34mm | |
| DC Voltage Resolution | 100 mV dc | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| Maximum Operating Temperature | 50°C | |
| Length | 249mm | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | |
| Width | 85mm | |
| Weight | 395g | |
| Height | 45mm | |
| True RMS | Yes | |
| Functions Measured | Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | |
| Battery Type | AA IEC LR06 | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Level | CAT III, CAT IV | |
| Maximum AC Current Measurement | 600A ac | |
| Display Type | LCD Backlight | |
| Power Source | Battery | |
| Safety Category Voltage | 1000V | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Clamp Meter | ||
Resistance Resolution 100mΩ | ||
Maximum DC Current Measurement 600A dc | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 6kΩ | ||
Model Number 374 FC | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
AC Current Resolution 100mA | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Resolution 100mV ac | ||
Maximum Jaw Opening 34mm | ||
DC Voltage Resolution 100 mV dc | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
Maximum Operating Temperature 50°C | ||
Length 249mm | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | ||
Width 85mm | ||
Weight 395g | ||
Height 45mm | ||
True RMS Yes | ||
Functions Measured Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | ||
Battery Type AA IEC LR06 | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Level CAT III, CAT IV | ||
Maximum AC Current Measurement 600A ac | ||
Display Type LCD Backlight | ||
Power Source Battery | ||
Safety Category Voltage 1000V | ||
Vrijgesteld
- Land van herkomst:
- MY
Fluke Clamp Meter, 600A Maximum AC Current Measurement, 1000V Maximum DC Voltage Measurement - FLUKE-374 FC
Features & Benefits
• 600A jaw range with 2500A flexible-probe compatibility for large conductors
• 1000V measurement capacity with CATIII1000V and CATIV600V safety ratings
• High-accuracy DC current ±2%rdg+5 digits for precise diagnostics
• Resistance and capacitance ranges to 6000Ω and 1000μF for component checks
• Bluetooth wireless output to log and transmit readings remotely
Applications
• Ideal for load balancing and power-quality checks in distribution panels
• Used for preventive maintenance where remote logging reduces exposure
• Can be used for installation verification on 1000V-rated electrical systems
• Used with flexible probes to measure large busbars and multi-core cables
Which batteries power the instrument and how are they replaced?
How does the flexible probe extend measurement capability?
What environmental limits affect operation at elevated humidity?
How does the instrument handle measurements on variable-frequency drives?
What ingress protection and standards apply to storage and transport?
Gerelateerde Links
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 378 FC Clamp Meter CAT IV 600 V Non-Contact Voltage
- Fluke 374 Clamp Meter Max Current 2.5kA ac CAT III 1000 V, CAT IV 600 V
- Fluke 374 Clamp Meter Max Current 2.5kA ac CAT III 1000 V, CAT IV 600 V With RS Calibration
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 377 FC Clamp Meter CAT III

