Siemens 4 Pole Type A Residual Current Circuit Breaker, 63A 5SM3, 300mA

  • RS-stocknr. 395-878
  • Fabrikantnummer 5SM3646-6KL
  • Fabrikant Siemens
Datasheets
Wetgeving en compliance
N.v.t.
Land van herkomst: DE
Productomschrijving

5SM3 Series, Undelayed Type A, 4-pole, Left-Side N Connection

RCCB for alternating and pulsating DC residual currents
Option for power connection from above or below
Tunnel terminals with wire protection on both sides
Combination terminal at the bottom for simultaneous connection of busbars and conductors
Safe for fingers and overhands according to DIN EN 50274 (VDE 0660 part 514)
Mounts to DIN rail (TH 35 to DIN EN 60715)
Behind-panel depth 70 mm

Standards

IEC/EN 61008-1, IEC/EN 61008-2-1, IEC/EN 61543

Approvals

VDE 0664-10, VDE 0664-11, VDE 0664-30

Approvals

VDE 0664-10, VDE 0664-11, VDE 0664-30

Standards

IEC/EN 61008-1, IEC/EN 61008-2-1, IEC/EN 61543

Siemens FI circuit breaker

Specificaties
Kenmerk Waarde
Current Rating 63A
Number of Poles 4
Trip Sensitivity 300mA
Tripping Characteristics Type A
Voltage Rating 400V
Series 5SM3
Tijdelijk niet op voorraad – voor levertijd of een alternatief product neem contact op via Live Chat of zoek een vergelijkbaar product op de website.
Prijs Each
180,00
(excl. BTW)
217,80
(incl. BTW)
Aantal stuks
Per stuk
1 +
€ 180,00
Related Products
Designed to be used in conjunction with the ...
Description:
Designed to be used in conjunction with the Allen Bradley 100-C contactor range to provide type 2 co-ordination without oversizing of the contactor, in rating up to 22kW. The breaker may be customised to suit individual requirements. Trip Class 10Short ...
Compact and functional designThe new F200 B RCCBs ...
Description:
Compact and functional designThe new F200 B RCCBs feature an innovative design that makes the products compact. Indeed, the two-pole device is the first one on the market that is built in just two modules and its compact dimensions ensure ...
The ABB F200 RCCB Series provide ground fault ...
Description:
The ABB F200 RCCB Series provide ground fault protection by monitoring the leakage of current to ground when used in conjunction with standard MCBs. The F200 series are compact DIN rail mounted RCCBs and feature a wide range of trip ...
RCBO's : DIN rail mounting with an operating ...
Description: