Productomschrijving

COAXTRAB® coaxial video protector adaptor, 75 Ω

COAXTRAB is a surge protector adaptor designed to protect video signal transmission lines using BNC connectors.
It integrates components that eliminate interference in Differential Mode (between the core and the shielding) and in Common Mode (between the core (or the shielding) and the earthing).
It may be installed hassle-free in connections, even existing connections.
The IN input (female connector) of the connector must be oriented toward the source of interference and the OUT output (male connector) oriented toward the equipment that must be protected.
The earth bond connection must be created using the shortest path using the adaptor's 1.5 m long core.

System: 75 Ω
Connector: BNC
Maximum operating voltage: 5 Vdc
Nominal current: 185 mA
Rated discharge current (8//20 s): 10 kA
Output voltage limit for 1 kV/s in MD/MC: 13 V / 500 V
Priming time in MD/MC: 100 ns / 500 ns
Frequency limit (at -3 dB): 170 MHz
Series resistance: 22 Ω
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 20-11-2019, met een levertijd van 2 à 3 werkdagen.
Prijs Each
132,70
(excl. BTW)
160,57
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
€ 132,70
10 - 19
€ 122,08
20 - 24
€ 115,98
25 - 49
€ 112,53
50 +
€ 109,71
Related Products
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...
Low-resistance enhanced surge protector suitable for twisted pair ...
Description:
Low-resistance enhanced surge protector suitable for twisted pair signalling applications. Low let-through voltage between all linesVery low (1Ω) in-line resistanceHigh (1.25A) maximum running currentWide bandwidthSturdy, flame retardant, ABS housingRemovable DIN rail foot for easy installation. Product can also ...
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...